Diverse GENIUS-II 소유자 매뉴얼 - 페이지 12
{카테고리_이름} Diverse GENIUS-II에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Diverse GENIUS-II 20 페이지. Genius-ii power supply
Battery Connection/Disconnection Procedure
WARNING: Sparks have the potential to cause an explosion should
combustible gases be present. The following procedures are designed to
minimise the risk of spark generation while connecting or disconnecting the
battery.
Battery Connection Procedure
The caravan battery should be connected as per the following steps.
1. Remove mains power to the Genius-II
Turn off the power switch on the Genius-II
2. Disconnect all loads
Turn off all 12 volt equipment connected to the Genius-II
3. Connect the positive battery terminal.
4. Connect the negative battery terminal.
If the battery negative is connected to chassis, ensure a connection exists from
chassis to the "Bat –VE" terminal of the Genius-II.
Battery Disconnection Procedure
The caravan battery should be disconnected as per the following steps.
1. Disconnect all loads
Turn off all 12 volt equipment connected to the Genius-II or disconnect the loads
using the remove load-disconnect switch.
2. Remove mains power to the Genius-II
Turn off the power switch on the Genius-II
3. Disconnect the negative battery.
4. Disconnect the positive battery terminal.
Batteries
Note: This battery charger is rated to charge a single 12 V (up to 6 cells) lead
acid battery of up to 100 Ah capacity. Charging current is limited to 15 A.
When using batteries with this product always consult with the battery
manufacturer for a detailed description of the installation, use and maintenance of
the battery.
Ensure the battery has been charged for several days before a major camping trip
(Leave the Genius-II power supply on for at least 2 days, preferably 5 days, with
battery connected.)
12