Diversified Power International Accusense Charge 1-48C017C Series 사용 설명서 - 페이지 10
{카테고리_이름} Diversified Power International Accusense Charge 1-48C017C Series에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Diversified Power International Accusense Charge 1-48C017C Series 14 페이지. Fully automatic battery charger
WARNING: DO NOT OPERATE THE CHARGER IF IT IS
MALFUNCTIONING. PERSONAL INJURY OR PROPERTY DAMAGE
COULD RESULT.
If any of the three red L.E.D.s flash, the charge cycle has terminated
prematurely. An abnormal charging condition was detected and charging
stopped due to a Charge Error Condition. Refer to the following Charge
Error Table for a description of the possible failure or condition.
Condition
Battery Voltage High
Battery Polarity Reversed
Output Overload
Charge Level Unbalanced
Excessive Charging Time
Excessive Overload
Excessive Discharged
Battery Voltage High. Charger's DC cord set possibly connected to a
•
battery pack with voltage higher than the output rating of the charger.
Battery Polarity Reversed. Check output connector and ensure proper
•
polarity. Remake connections.
Output Overload. While charging, and, for example, under severe
•
motor loading, charger may shut down. This error is not very likely to
occur.
Charge Level Unbalanced. Caused by unbalanced battery condition.
•
Example: some batteries are at a much higher state of charge than
others. This may require replacement of the batteries. Refer to the
Equipment's Operators manual for instructions on servicing the
battery pack.
Excessive Charging Time. Occurs when charging took too long.
•
Possible causes include: use of a battery load that is draining energy
from the battery while the charger is trying to charge that same
battery, aged or unbalanced battery conditions, etc.
CHARGE ERROR TABLE
Flashing L.E.D.s
Power
Off
Off
Off
Flash
Flash
Flash
Flash
10
Abnormal
Off
Flash
Flash
Off
Off
Flash
Flash
Detection
Flash
Off
Flash
Off
Flash
Off
Flash