Balmar ARS-5 설치 및 운영 매뉴얼 - 페이지 13

{카테고리_이름} Balmar ARS-5에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Balmar ARS-5 16 페이지. Multi-stage voltage regulator
Balmar ARS-5에 대해서도 마찬가지입니다: 설치 및 운영 매뉴얼 (20 페이지), 빠른 시작 매뉴얼 (2 페이지)

Balmar ARS-5 설치 및 운영 매뉴얼
Additional Regulator Features
Small Engine Mode
In situations where additional power is needed for propulsion, the ARS-5 provides the option to manually reduce regula-
tor field output by approximately one half. This option, called Small Engine Mode, can be accessed by creating a direct
pathway between the positive and negative Alternator Temperature Sensor terminals. This
can be done by splicing into the positive and negative wires of the Alternator Temperature
Sensor cable (MC-TS-A) with a switched wire. With the switch in the OFF position, the
Alternator #1 Temperature Sensor will work normally. With the switch in the ON position,
the regulator will reduce field output by approximately 50%.
To enable the Small Engine Mode:
1.
If the Alternator Temperature Sensor cable is being used, replace the female termi-
nal connectors on the cable with Multi-Stack Connectors (Ancor Part # 230612).
2.
Install a standard ON/OFF switch in a location that's easily reached from the helm.
3.
Run wires from the switch back to the positive and negative terminals of the Alterna-
tor Temperature Sensor terminals.
4.
Add appropriate connectors to the switched wires and connect to the positive and
negative terminal connections.
Dash Lamp
The ARS-5 provides a Dash Lamp circuit that's capable of providing a signal to a user supplied and installed audible or
visual alert if the following issues were to occur while the regulator is in operation;
Low Battery Voltage <12.7V
High Battery Voltage >15.5V
High Alternator Temperature >226
High Battery Temperature >125
Alternator Failure (No voltage on stator).
NOTES:
˚F/ 108˚C (Requires installation of MC-TS-A sensor.) Temperature adjustable.
˚F/52˚C (Requires installation of MC-TS-B sensor cable.)