Thermostat Control Description and Function
!
The L.E.D., Light Emitting Diode, referred to is an
electronic device providing illumination. The control
has a three-digit L.E.D. display. When the warming
cabinet is in operation, the L.E.D. will show the
chamber's internal temperature. The display will also
show programming and diagnostic information.
ON/OFF Rocker Switch
The Power On/Off Rocker Switch positions may be
marked with the international "I" for On and "O" for Off.
UP/DOWN Arrow Rocker Button
The up/down arrow rocker button is
used to increase or decrease the set-point
temperature. The minimum set-point
temperature is 90°F (32°C) while the
POWER
maximum set-point temperature is
200°F (93°C).
SET Button
The SET button is used to display the
SET
current set-point temperature or program
a new set-point temperature. Pushing the
SET button once will display the set-point
temperature value for five seconds.
Holding the SET button allows the pro-
gramming mode to become active.
O P E R AT I O N
200
SET
# 8 2 4 O p e r a t i o n a n d C a r e M a n u a l • 6.
prg
L.E.D. Display
The L.E.D. display will show the
L.E.D.1
set-point temperature value when
programming, or the warming chamber's
temperature when calling for heat. When
200
programming a new set-point temperature,
the L.E.D.1 indicator with blink. When a
°F
new set-point temperature is chosen, the
CHAMBER
Chamber Temperature L.E.D. will flash
TEMPERATURE
L.E.D.
three times to confirm.
HEAT INDICATOR L.E.D.
The Heat Indicator L.E.D. will illuminate
and remain lit while the unit is calling for
heat. It will go out when the air tempera-
ture inside the warming chamber reaches
the
set-point temperature on the control.