ACCESS200 installation guide for SNET
1. Install readers
Fix the base part to a single gang box or directly to the mounting surface.
Use 3 mm diameter countersunk head screws. Heads must not stand out
more than 1 mm from the base surface.
When using stranded wires, make sure there are no wires outside the
cages of the pluggable cage clamp.
To avoid rain interference, mount outdoor keypad readers upright or
at a protected spot. Otherwise, ensure large water drops are wiped off
if readers are malfunctioning.
Pigtail cable connection / Molex Pico-SPOX (outdoor/potted
versions) stranded, AWG28, power Red&Black AWG 24
Color
Connector pin #
White/Orange
Orange
White/Green
Green
Red/White
Black/White
Red
Black
White/Blue
Blue
White/Brown
Brown
2. Optional: Set bus address
This step is only needed if you want to assign each reader an individual address: Present a
BALTECH AdrCard to the reader, and wait for the signal indicating the desired address.
Learn more:
docs.baltech.de/bus-address
Note: The documentation refers to the OSDP protocol, but the steps for SNET
are the same as both protocols are based on RS-485.
BALTECH AG
Phone:
Lilienthalstrasse 27
Fax:
85399 Hallbergmoos
Mail:
Germany
Website:
Signal/funct.
1
WIE_D0/RS485A
2
WIE_D1/RS485B
3
LEDGN
4
LEDRD
5
USB Data -
6
USB Data +
7
+VIN
8
GND
9
GND
10
REL_WC
11
REL_NO
12
REL_NC
+49 (811) 99 88 1-0
+49 (811) 99 88 1-11
www.baltech.de
Connector and pins
(reader rear view)
J8 Pluggable cage clamp
(indoor versions)
Pin #
Signal/funct.
J8-1
GND
J8-2
+Vin
J8-3
WIE_D0/RS485A
J8-4
WIE_D1/RS485B
J8-5
LEDGN
J8-6
LEDRD
J8-7
REL_WC
J8-8
REL_NO
J8-9
REL_NC
v1.1