5. To gain access to the inside of the filtration housing, remove the housing access doorknobs by turning
counter-clockwise (for housings equipped with swivel latches: do not remove doorknobs; loosen and swivel
door bolt out from door corner retainer). Pull the access door straight towards you to remove.
6. To install prefilter(s) (if required for the application), push the prefilter inside the housing using the slide
track. Make sure to install prefilters with the pleats in the vertical position.
7. To install primary filter(s)/adsorber(s), release the locking mechanism handle from the handle latch. Slowly
open the locking mechanism by pulling the handle fully open. Load the filter(s)/adsorber(s) into the housing
with the fluid seal channel towards the housing knife-edge (opposite the locking mechanism). Make sure
the filter/adsorber is correctly orientated when placing inside of the filtration housing. The filter clips should
be positioned on the top and bottom of the filter (see pictures). The filter shall be installed with the pleats,
or separators in the vertical position. Install adsorbers with the carbon beds in the horizontal position.
Push the filter(s)/adsorber(s) to the back of the filtration housing until it stops. For filtration housings that
contain more than one filter/adsorber, it may be necessary to push one filter as far inside the housing as
possible. Next, install the second filter to help push the first filter to the back of the housing. When all the
filter(s)/adsorber(s) are installed correctly in a multi-wide housing, the last filter/adsorber edge should be
aligned with the sealing surface edge.
Correct filter installa-
tion, with locking tray
angle between clip and
filter frame
7
Incorrect filter installa-
tion, with locking tray
angle outside clip and
filter frame