THERMOSTAT & INDICATOR LIGHT SEQUENCE
THERMOSTAT & PILOT LIGHT SEQUENCE
Whenever the thermostat is turned "ON," the
indicator light will indicate the power ON/OFF
condition of the heating cable, and consequently,
the cycling of the cabinet as it maintains the dialed
cavity temperature. If this light does not illuminate
after normal start-up, the main power source,
thermostat, and/or indicator light must be
checked. If the warming cabinet does not hold
the temperature as dialed, the calibration of the
thermostat must be checked. If the warming
cabinet fails to heat or heats continuously with the
thermostat "OFF," the thermostat must be initially
checked for proper operation. If these items are
checked and found to be in order, a continuity and
resistance check of the heating cable should be
made. SEE WIRE DIAGRAM INCLUDED WITH THE
UNIT.
S E R V I C E
500-PH/GD (Rev . 1) • Installation/Operation/Service Manual • 11
THERMOSTAT CALIBRATION
The thermostat is precision calibrated at the
factory. Normally, no adjustment or recalibration
is necessary unless the thermostat has been
mishandled in transit, changed or abused while in
service. A thermostat with a sensing bulb operates
on hydraulic pressure, consequently, any bending of
the bulb results in a change in its volume, and alters
the accuracy of the thermostat calibration.
A thermostat should be checked or recalibrated by
placing a quality, thermal indicator at the center
of an empty holding cavity. DO NOT CALIBRATE
WITH ANY FOOD PRODUCT IN THE CABINET. The
thermostat should be set, and should be allowed to
stabilize at that setting for a minimum of one hour.
The center of the thermal swing of the air
temperature within the cabinet should
approximately coincide with the thermostat setting.
If calibration is necessary, the calibration screw
should be adjusted with great care. The calibration
screw of the thermostat is located in the thermostat
dial shaft. With the shaft held stationary, a
minute, clockwise motion of the calibration screw
appreciably lowers the thermostat setting. A
reverse, or counter-clockwise motion appreciably
raises the
thermostat setting. After achieving the desired
cycling of the thermostat, the calibration screw
must be sealed. Place a few drops of enamel sealant
directly on the calibration screw. (Red nail polish or
equivalent is acceptable.)