ELECTRICAL CONNECTION

1. An identification tag is permanently mounted
on the unit.
2. If necessary, a proper receptacle or permanent
wiring for this unit must be installed by a
licensed electrician in accordance with
applicable local electrical codes.
3. Plug the unit into a properly grounded
receptacle ONLY, positioning the unit so the
power supply cord is easily accessible in case
of an emergency. Arcing will occur when
connecting or disconnecting the unit unless
all controls are in the OFF position.
ELECTRICAL CONNECTIONS MUST
BE MADE BY A QUALIFIED SERVICE
TECHNICIAN IN ACCORDANCE WITH
APPLICABLE ELECTRICAL CODES.
I N S T A L L A T I O N
E L E C T R I C A L
/
VOLTAGE
PHASE
CYCLE
HZ
208V
1
50/60
230V
1
50/60
/
VOLTAGE
PHASE
CYCLE
HZ
208V
1
50/60
230V
1
50/60
/
VOLTAGE
PHASE
CYCLE
HZ
208V
1
60
230V
1
50/60
#809 Operation & Care Manual •
230V: To prevent an electrical shock hazard
between the appliance and other appliances or
metal parts in close vicinity, an equalization-
bonding stud is provided. An equalization
bonding lead must be connected to this stud and
the other appliances / metal parts to provide
sufficient protection against potential difference.
The terminal is marked with the following
symbol.
NOTE: The appliance must be connected
to an electrical circuit that is protected by
an external GFCI outlet.
HFM-30
kW
AMPS
5.2
1.1
6-15
NEMA
15A, 250V
AVAILABLE UPON REQUEST
HFM-48
kW
AMPS
10.5
2.2
6-15
NEMA
15A, 250V
AVAILABLE UPON REQUEST
HFM-72
kW
AMPS
15.8
3.3
6-20
NEMA
20A, 250V
AVAILABLE UPON REQUEST
5.
To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70.
In Canada, all
electrical connections are to be made
in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
P
PLUG
P
PLUG
P
PLUG