Alto-Shaam 1000-UP/STD 작동 및 관리 매뉴얼 - 페이지 6

{카테고리_이름} Alto-Shaam 1000-UP/STD에 대한 작동 및 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Alto-Shaam 1000-UP/STD 17 페이지. Food holding cabinet pass-through & reach-in, manual or electronic control

Alto-Shaam 1000-UP/STD 작동 및 관리 매뉴얼
T R O U B L E S H O O T I N G C H E C K L I S T • E L E C T R O N I C C O N T R O L
R e p a i r s s h o u l d b e m a d e b y a u t h o r i z e d s e r v i c e a g e n t s o n l y .
TROUBLE
Unit does not operate.
No display in electronic control.
Cannot control temperature but
sensor and electronic control
checks O.K.
Temperature readout incorrect.
Remember to
disconnect
the unit from
power source
before
cleaning or
servicing.
Electronic Control . . . . . . (Factory Installation only)
Electronic Control
➥with multiple timers . . . . (Factory Installation only)
Bumper, full perimeter . . . . . . . . . . . . . . . . . . .
Casters, 3" (76mm)
Casters, 5" (127mm) . . . . . . . . . . . . . . . . . . . . .
HACCP with
Kitchen Management . . . . . . . . . . . .
Legs, 6" (152mm) . . . . . . . . . . . . . .
POSSIBLE CAUSE
Insufficient power supply.
Defective power cord or plug.
Faulty power supply board.
Faulty electronic control.
Faulty relay
Heating element grounded.
Dirty or faulty sensor.
Faulty control.
OPTIONS & ACCESSORIES
.44119
. . . . . . . . . . . .
14227
.4007
CONTACT FACTORY
5205
#838/44 Operation and Care Manual •
Check power source.
Check and replace if necessary.
Check line voltage for 24V across
pins 7 and 8 on the power supply board
and across terminals J9 and J10 on the
electronic control.
Replace control.
Replace relay.
Replace element.
Check sensor at 32°F (0°C).
If Ohm reading is 100, replace display.
If Ohm reading is not 100, replace sensor.
C A B L E H E A T I N G S E R V I C E
K I T No.
(one kit per compartment)
includes:
CB-3044
Cable Heating Element
CR-3226
Ring Connector
IN-3488
Insulation Corner
BU-3105
Shoulder Bushing
BU-3106
Cup Bushing
ST-2439
Stud
NU-2215
Hex Nut
SL-3063
Insulating Sleeve
TA-3540
Electrical Tape
Shelves — Stainless Steel Wire
➥Reach-in
. . . . . . . . . . . . . .
➥Pass-through . . . . . . . . . . . . .
Wire Pan Grid
➥18" x 26" Sheet Pan Insert . . . . . . .
Window Door . . . . . . . . . . . . . . .
➥(Factory Installation only)
Left hand door swing
➥(Factory Installation only)
5.
REMEDY
4874
108 feet
4
1 foot
4
4
4
8
4
1 roll
SH-2325
SH-2346
PN-2115
15148