ELECTRICAL WIRING
The conductors forming the signal carrying cable connected to the microswitch
( Fig.3 ) must have an adequate cross-section so that the current density,
in each conductor, is no higher than 4 A/mm². One of these is used only
for the earthing of the level gauge.
The cross-section of the conductors must also be adequate in relation to the
length of the cable used to avoid a drop in voltage along the cable over
the values prescribed by the regulations on the subject.
It is likewise reccomended to use flexible cables with an adequate outside
diameter for the fair-leads used ( not supplied ) to ensure a perfect seal of
the cable clamp on the signal carrying cable.
certified ATEX Exd IP65 or IECEx Exd IP65 M16x1.5.
Use Faston cable terminals ( 6.3 x 0.8 mm. ) to connect the microswitch terminals and the ground connection.
CAUTION:
In the terminal board compartment, the connection for Faston type terminal whose position is marked
by the ground symbol on the printed circuit ( Fig.3 ) is used for the earthing the level gauge. The yellow-green
conductor ( green only for the USA ) of the signal carrying cable must be
connected to this terminal. The ground connection of the float level gauge,
through the yellow-green conductor, is compulsory.
On the external level gauge casing side, placed side by side to the cable
inlet, a second connection point is present for the external ground connection
executable with a screw M5 and an eyelet cable terminal.
-
The external earthing has to be carried out by the installator.
-
The equipment has to be protected against impact and electrostatic inside
the tank.
-
The user has to protect the equipment circuits with fuses against short circuit.
-
The max. surface temperature is without dust and not safety distance.
REFERENCE FIGURES
137
M16 x 1.5
137
M16 x 1.5
PFG-LP-C
Outside casing ground
The manufacturer CAMLOGIC Snc declares under its own responsability that the product PFG-LP answers to the requisites
of the European Directive 2014/34/EU in consideration of the standards : IEC EN 60079-0 IEC EN 60079-1 IEC EN 61241-0 IEC EN 61241-1.
Marking:
II 2GD Ex d IIB T4 Ex tD A21 IP65 T135 °C
The permitted range ambient temperature is
Notified corporate body that releases the examination TÜV NORD. Crt. number: TÜV 08 ATEX 362388 X - IECEx QAR TUN 08.0033.
Corporate body entrusted of the periodic overseeing TÜV ITALIA.
Instructions Manual No. 00956 19.10 - Rev. 00
part of it may be disclosed without written authorization from CAMLOGIC S.n.c.
This manual, even after the sale of level gauge, is lent and remains the property of the Manufacturer.
SGC2008
392
255
18
60
45
150
ø 66
PFG-LP
392 ~
255 ~
18
60
3
Float ø 52 x150
DN40 COUNTERFLANGE
4 holes ø 18 to 90°
UE
DECLARATION OF CONFORMITY
Use exclusively cable entries
MAINTENANCE
CAMLOGIC float level gauges for liquids need no
routine maintenance. Take care the external cleaning
of the level gauge, the dust accumulation doesn't
have to exceed a thickness of 5 mm.
WARRANTY
CAMLOGIC S.n.c., in addition to the terms of the
supply contract, guarantees its products for a
period of twenty-four ( 24 ) months from the date
of shipment.
This warranty is expressed only in the repair or
replacement free of charge of parts that, after
careful examination by the Manufacturer, turn out
to be difective.
Warranty, excluding all liability for direct or indirect
damage, is considered to be restricted to only
defects in materials and has no effect if the parts
returned turn out to have been anyhow dismantled,
tampered with or repaired by anyone other than
the Manufacturer.
Warranty likewise excludes damage deriving from
negligence, carelessness, bad or improper use of
the level gauge, or from bad handling by the
operator and faulty installation.
Warranty is moreover forfeit if non-genuine spare
parts have been used. A returned level gauge, even
if under warranty, must be shipped carriage free.
Marking IECEx: Ex d IIB T4 Gb - Ex tD A21 IIIC T135 °C Db IP65.
All the information contained in this manual is confidential and no
Inside casing ground
Faston
6.3x0.8mm.
1 2 3
1- N.o. contact
2- Com. contact
3- N.C. contact
00956 19.10 - Rev. 00