Dixon Bayco DBC Series 유지 관리 및 운영 지침 - 페이지 4
{카테고리_이름} Dixon Bayco DBC Series에 대한 유지 관리 및 운영 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Dixon Bayco DBC Series 13 페이지. 3" dry disconnects
Disassembly
1. Remove MAIN GASKET from BODY. If MAIN GASKET is a PTFE
Encapsulated style, it is acceptable to leave the MAIN GASKET in
place.
2. Insert a BLANK ADAPTER (an adapter end from a DBA style Dry
Disconnect Adapter) into the coupler and close the CAM ARMS.
3. Remove the SCREW from the center of the POPPET. Discard the
O-RING found under the head of the SCREW.
4. Loosen the SET SCREW found in the center of the POPPET using
a 5/16" hex key. Do not remove the SET SCREW.
5. Rotate LEVER to the open position and unthread the POPPET
from the POPPET STEM.
6. The next step is to remove the SEAL CYLINDER. Follow these
instructions carefully to avoid injury and damage to the product. Keep
your face and head off to the side of the open end of the coupler
body. DO NOT look directly down into the POPPET area of the
coupler. If the SEAL CYLINDER is released un-expectedly, injury will
result.
a. While maintaining 50 to 55 pounds of force against the
SEAL CYLINDER, open the two CAM ARMS and rotate and
hold in the full open position using your fingers and thumb of
the hand not pressing down on the BLANK ADAPTER.
b. With the two CAM ARMS held open, slowly decrease the
holding force on the BLANK ADAPTER allowing it to move
out of the BODY.
c.
may temporarily catch on the O-RING that seals the
SEAL CYLINDER. DO NOT remove all holding force on
the BLANK ADAPTER until the guide BUTTONS are free
and clear of the SEAL CYLINDER O-RING.
d. If the guide BUTTONS prevent the SEAL CYLINDER from
releasing from the BODY, gently move the SEAL CYLINDER
in an orbital fashion while pressing the SEAL CYLINDER
down into the BODY and then allowing it to come back into
contact with the O-RING.
4
DBC 3" Series Dry Disconnects
The guide BUTTONS on the SEAL CYLINDER
877.582.3569
DBC 3" SERIES