Dixon LGH5000 Series 유지 관리 및 운영 지침 - 페이지 7

{카테고리_이름} Dixon LGH5000 Series에 대한 유지 관리 및 운영 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. Dixon LGH5000 Series 8 페이지. Guard bar hinge

4. For LGH5000 and LGH5000API, install the 5000AIHD (purchased separately)
horizontally onto the bottom of the left bracket (1) through the threaded holes on the
left bracket (1). The button of the 5000AIHD should face the roller (12) on the left arm
(2). For LGH5000-001, install the 5000AIHD vertically onto the AI bracket (22) and
install the AI bracket (22) with the 5000AIHD to the left bracket (1). The button of the
5000AIHD should face up.
5. Install the tension springs (10) to link the arms (2 and 4) to the brackets (1 and 3).
Check the swing action to make sure there are no obstructions. Check and operate
the locking rod (21) to make sure that it can properly lock and unlock the left arm (2),
when the guard bar is up and down.

OPERATION:

To open the guard bar for hose connection, push and hold the locking rod (21) out of the
locking hole on the left arm (2) and lift the guard bar. Release the locking rod (21). The
locking rod (21) will retract into the other hole on the left arm (2). The guard bar will be
locked in place.
After the hoses are disconnected, hold the guard bar, push and hold the lock rod (21) out of
the locking hole on the left arm (2). Swing the guard bar back so the arms (2 and 4) rest on
the brackets (1 and 3). Release the locking rod (21) and it will retract into the other hole on
the left arm (2). The guard bar will be locked in place.
090119 REV1 2017/09/01
877.582.3569
7