Altra Industrial Motion Warner Electric PB-120 설치 지침 매뉴얼 - 페이지 16

{카테고리_이름} Altra Industrial Motion Warner Electric PB-120에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Altra Industrial Motion Warner Electric PB-120 18 페이지. Primary brakes

Send Quote Requests to [email protected]
PB-400 Flange Mounted Brake
For Bore & Keyway sizes
see chart below .
Std . Armature
Antibacklash
Armature
Armature View
Removable plug
in ends for 1/2"
conduit .
5 .625/5 .623
Pilot diameter
Field View
*Mounting holes are within .010 of true position relative to pilot diameter .
Customer Shall Maintain:
1 . Squareness of brake mounting face with armature hub
shaft within .006 T .I .R .
2 . Concentricity of brake mounting pilot diameter with
armature shaft within .010 T .I .R .
16 Warner Electric • 800-825-9050
3 .750
4 .687 Max .
45°
.296/ .280 diameter (4) holes equally
spaced on 5 .000 diameter
Send Quote Requests to [email protected]
Call +1(800)985-6929 To Order or Order Online At Warnerelectricparts.com
Call +1(800)985-6929 To Order or Order Online At Warnerelectricparts.com
.015 When New
.328 Max .
Std . Arm .
1 .250
4 .234
Max .
Dia .
1 .640
Anti . Arm .
.187 (Std .)
.218 (Anti .)
.343
.875 (Std .)
.843 (Anti .)
Bore and Keyway Di men sions
4 .250
Armature Bore Dia.
Sq .
.501/ .500
* .563/ .562
.626/ .625
* .688/ .687
.751/ .750
.876/ .875
*Available on special order only .
Shaft Sizes
Static Torque
Maximum Speed
Standard Voltage
1 .546
.953
3 .562
1 .875
1 .873
Pilot Dia .
1/4-20
UNC-3A
.093
.015
1 .312
.609 Max .
1 .500
2 .328 (Std .)
2 .359 (Anti .)
Keyway
.125 x .062
.187 x .093
.500 – .875
270 lb . in .
4,500 rpm
D .C . 6, 24, 90
P-201-WE • 819-0480