OPERATION
1. The pump must be submerged at all times during normal opera-
tion. Do not run pump dry.
2. Make sure that the float switches are set so that the pump stops
before the pump runs dry or breaks suction. If necessary, adjust
float switches to achieve this.
3. The motor bearings are lubricated internally. No maintenance is
required or possible on the pump.
Model
P10D
P20D
P30D
Submersible
Pump
Figure 1: Insert a piece of 3" PVC pipe in the bottom of
the motor to raise the pump in the tank.
Table 1: Recommended Fusing Data
60 Hz/1 Phase 2-Wire Cable
Volts/Hz/
HP
Phase
1/2
115/60/1
1/2
115/60/1
1/2
115/60/1
3" Pipe
3" to 4" Pipe
Adapter
4" Pipe
Max
Load
Amps
11.0
9.5
9.5
250(76)
200(61)
150(46)
20 GPM
100(30)
50(15)
10 GPM
0(0)
0
10
(0)
(38)
Figure 2: Performance in Feet of Head at Gallons Per
Minute (M@LPM).
3
Locked
Fuse Size
Rotor
Standard/
Amps
Dual Element
30.0
15
30.0
15
30.0
15
20 GPM+1
30 GPM
30
20
(114)
(76)
(151)
Flow in USGPM (LPM)
40