ClearWater Ozone Systems PRO400 설치 및 유지 관리 매뉴얼 - 페이지 7

{카테고리_이름} ClearWater Ozone Systems PRO400에 대한 설치 및 유지 관리 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ClearWater Ozone Systems PRO400 8 페이지. Circulation system

• Disconnect power from unit before any maintenance procedures.
• Check valve - replace diaphragm check valves, annually.
• Intake filter - replace intake filter, annually.
Electrical - 120 VAC 60 Hz 2.0 Amps
- 240 VAC 50 Hz 1.6 Amps
Dimensions - 20" H x 12-3/4" W x 5" D
Maximum Head - 120VAC 60Hz: 5 gpm @ 22TDH, 9.5 psi
BATTERY
Replace only with Lithium battery type CR2032.

REPLACING THE BATTERY

Battery should be available locally should it need
to be replaced. Disconnect the power to the unit
and remove the front cover, retaining screws and
slide front cover off. Than remove 3 screws to
remove timer plate (See figure1, page 4). To replace
the battery, open the battery compartment on back of
timer plate and install new battery. Replace parts in
reverse order.
*NOTE: If installing new timer, remove plastic tab before closing unit.
- 220VAC 50Hz: 5 gpm @ 14TDH, 6.0 psi
PLASTIC TAB
6