EDI LMD Series 운영 매뉴얼 - 페이지 10
{카테고리_이름} EDI LMD Series에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. EDI LMD Series 15 페이지. Deflectometer, inductive loop monitor
EDI LMD Series에 대해서도 마찬가지입니다: 운영 매뉴얼 (15 페이지)
2.6.1 CURRENT FAULT
If a fault is detected, both the DET (Red) and FLT (Yellow) LEDs continuously emit a
sequence of flashes and the DEFLECTOMETER will display the letter "F". Each type of
fault is identified by a different flash sequence followed by a one second pause:
Flash Sequence
1 flash
2 flashes
3 flashes
2.6.2 PREVIOUS FAULT
If the fault condition is removed, the DET indicator and the channel output will return to
normal operation. The FLT indicator will continue to flash indicating that a fault had
previously occurred. This Previous Fault indication may be reset by momentarily pressing
the MODE and FREQ buttons simultaneously. See section 2.5.2.
Eberle Design Inc.
LMD602 and LMD604 Series
Operations Manual
Open Circuit Loop (or Inductance too high)
Shorted Circuit Loop (or inductance too low)
>25% Change in Inductance
Fault
Page 7