EDI DA-300 운영 매뉴얼 - 페이지 4

{카테고리_이름} EDI DA-300에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. EDI DA-300 7 페이지. Io tester

EDI DA-300 운영 매뉴얼
Overview
The Data Aggregator DA-300
signals as well as detector outputs from a traffic cabinet. The DA-300
outputs. Production testing and demonstration of a DA-300
traffic cabinet and thus a bench tool capable of simulating these inputs to and receive the
outputs from a DA-300
®
The DA-300
IO tester (model DIOT) was created to fulfill this need. It provides user
adjustable DC and AC voltages to a DA-300
®
300
relay outputs displaying the contact statuses.
The DIOT supports a simple intuitive user interface consisting of 36 labeled toggle switches
(one for each DA input), Two front panel rotating knobs (one for DC adjust and one for AC
adjust) and 8 LEDs (one for each relay output). The adjustable AC and DC voltages are
read by two different meters.
Labeled toggle switches apply or remove either AC or DC voltages from an AC or
DC input respectively.
Other labeled toggle switches simulate discrete detector input states.
The left top panel knob when rotated clockwise increases the DC voltage, while
rotating it counterclockwise, the DC voltage drops.
The right top panel knob when rotated clockwise lowers the AC voltage, while
rotating counterclockwise raises the AC voltage.
The front panel toggle switch labeled PWR, turns the tester on or off, when in the
"off" position all AC and DC voltages are removed from the inputs to a connected
®
DA-300
regardless of the status of their toggle switches. As a safety feature, if
the DIOT is still plugged in but turned off, the AC voltage will still be displayed.
Eberle Design Inc.
®
DA-300
Operations Manual
Section 1
GENERAL
®
provides the ability to monitor several DC and AC analog
®
unit is needed.
IO TESTER
®
®
simulating real inputs; and it receives the DA-
®
also generates relay
unit may occur outside a
Page 1