There are 2 different models of
lamp: Philips XOP7-OF and XOP 15-OF.
XOP-7 models for AC 90-120 volts AC, 200 volts for the following; XOP -15 models for AC AC
from 200 to 260 volts for 200 volts or more.
WARNING: Installing any other lamp may cause damage or may damage the
lamp Insurance
Important: Please use the bulb from the factory.
Replacement lamp
After the lamp cover with a green LED light bulb can tell you the last life; If the LED is not
bright, but light bulbs flashing, on behalf of the lamp has been aging; If the LED is not flashing,
the control signal may be a problem.
Replacement lamp
Warning: Check the lights before opening the front cover is off the power!!!
1. Before demolition of the lamp, wait 1 minute, so that the residual PCB board capacitance
electric charge electric shock.
2. Light body to be cooled down before open the lamp cover.
3. Make sure the power is disconnected
4. Please lamp disassembly required
Control operation
This section tells how to do ATMIC 3000
Data connection
ATMIC 3000
to provide the data connection 3-pin and 5 pin socket outlet in all the output
pin 1 ground protection, pin 2, then negative, then positive pin 3. There is no connection 4-pin
and 5 pin. Connection, data transmission is to use a data input line and a data output line. Data
cable connection
1. DMX signal input connector of the controller can use 3-pin or 5-pin socket.
2. Connect to the last one in the M-3000 plug the output of a signal termination to avoid signal
reflection interference.
Device attachment
·RS-485 device using a shielded twisted pair: standard cable in the long run, cannot guarantee
the reliability of data transmission control. 24 type cable for the 300 meters run. Long distance
running in the recommended installation of a large cable or signal amplifier.
·Output signal lines do not split into two signal lines output.
·Not to overload the connection. A signal line can connect a maximum of 32 ATMIC 3000 lights.