Altronic 6715 D 매뉴얼 - 페이지 14
{카테고리_이름} Altronic 6715 D에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Altronic 6715 D 20 페이지. Coaxial load resistor
3-8. Ducting. In many installations it will be necessary to duct the discharge air from the
Model 6715D to the exterior of the building. In some installations it will also be necessary
to supply inlet air from outside of the climate-controlled portion of the building.
The discharge air flow is approximately 325 SCFM at a maximum temperature of 250°F.
Due to the high temperatures involved, non-metallic duct materials should not be used for
the discharge duct, but may be suitable for inlet duct. Attaching a discharge duct to the
unit is easily accomplished:
1.
Remove the 10 torx head screws attaching the discharge grill.
2.
Then, replace the discharge grill with a discharge air duct adapter.
Suitable ducting can then be attached to the adapter. This duct should be as short as possible to
minimize back pressure. Design of the ducting and wall or ceiling penetrations should be
referred to a competent heating and air conditioning firm.
"Make-up air" is a ventilation term used to indicate the supply of outdoor replacement air
to a building in a controlled manner. It may be provided for the Model 6715D by ducting
into the room or by extending a supply duct to either intake grill of the blower enclosure
and installing a blanking plate on the other grill.
Make-up air will enter the building to equal the volume actually exhausted, whether or not
provision is made for this replacement. However, the actual exhausted volume may not
equal the design volume unless an adequate supply is provided.
3-9. Adjustments. No field adjustments are necessary or possible.
3
Preparation for Reshipment. No special measures are required to prepare the Model
-10.
6715D for reshipment. Care must be taken to protect the RF connector and to immobilize
the swivel flange. Packaging should provide protection against abrasion and impact.
6715D/Rev. Jul.2020
Page 14
Altronic Research Inc.