AIMS Power PWRIG100012120S 운영 매뉴얼 - 페이지 6

{카테고리_이름} AIMS Power PWRIG100012120S에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AIMS Power PWRIG100012120S 16 페이지.

AIMS Power PWRIG100012120S 운영 매뉴얼
 Prior to using this product please read this operation manual thoroughly. Inappropriate use may cause damage to the product!
Please check through this manual on your new inverter before operating.
I. Use of battery (DC power)
12V Battery: When using 500 watts of output (120V AC) with a 100A battery, you can use this product for 2 hours (4.2A used under 100W) in
optimal conditions.
24V Battery: When using 500 watts of output (120V AC) with a 100A battery, you can use this product for 4 hours (4.2A) used under 100W) in
optimal conditions.
48V Battery: When using 500 watts of output (120V AC) with a 100A battery, you can use this product for 8 hours (4.2A) used under 100W) in
optimal conditions.
II. Use of AC power outlet (120V AC)
The product has an output function of 120V AC.
Although the output AC cord is different based on thickness, 150 Ft. length can be used in general conditions.
III. Alarm display function (red LED)
 Output short circuit
 Output overload
 Over temperate protection
 Battery low voltage (alarm/LED)
 Battery high voltage (alarm/LED)
IV. Fan operation
Based on the 120V AC load of this product the fan automatically operates when the temperature increases.
Thermal fan engages at 113*F ±3*
6