Artidor AR-077 Series 사용자 설명서 - 페이지 12
{카테고리_이름} Artidor AR-077 Series에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Artidor AR-077 Series 16 페이지. Explosion-safe signal lights
For the model "with cable gland & terminals"
Follow the instructions as stated under the previous heading 'General'.
The signal light with cable gland & terminals is suitable for wall-mounting by using the bracket. It is also
suitable for assembly using a pipe clamp across the cylindrical part (D=60) of the housing. In that case,
remove the mounting bracket and reverse the cover of the connection compartment along with its
cover screws.
Ensure that the cable gland fits the individual cable used with respect to clamping size and type of
cable. If not, apply a suitable cable gland and make sure that it is approved for its application.
Connect an external earth wire to the earth boss and make sure that it is sufficiently connected to
ground.
The electrical power supply must be connected to (L) and (N) terminals in the connection
compartment. If a direct current power supply is used, reverse polarity of the power supply will not
affect the function or the safety of the signal light.
Additionally, an earth wire must be connected to the PE connection terminal, see the wiring diagram
below.
Remove the external insulation from the cable over a length of 150 mm.
Feed the cable into the connection compartment and fix the cable gland into place.
Connect the connection wires following the instructions as given in this manual in chapter (14)
"Instructions for connecting to the Ex e connection terminals".
Tighten all screws of all connection terminals and close the cover.
NOTE
For the 4-pole model (linking function), a 16
Amps limit of the transit current applies.
10.
Opening the housing
Compartment with lamp and electronics
The part of the housing that contains the lamp and the electronics is designed as flameproof Ex d and
contains no components that need direct access. It is therefore not accessible to the user. The housing is
User manual explosion-safe AR-077 signal light
Issue April 2020
Electrical connection of the terminals
12 / 16