TROUBLESHOOTING

PROBLEM: CRIMPER WILL NOT RUN AT ALL
The white rocker switch is also a circuit breaker. Check to see that the circuit breaker has not been tripped.
Check the wall outlet. Use of extension cords or outlets with inadequate power can damage the motor .
Do not run the crimper from a portable power source.
PROBLEM: CRIMP DIAMETER TOO LARGE
Check crimper calibration and recalibrate if required.
Incorrect die being used. Each die has a range of approximately 3mm (.120 in) above the closed diameter
of the die. The closed diameter is the die size stamped on the die face.
Incorrect setting of the micrometer. Check hose manufacturer's specifi cations.
Inadequate pump pressure. Check oil level in the pump. It should be 1-1/2 to 2 inches below the fi ll plug.
Replenish with ISO Viscosity Grade 46 hydraulic oil if necessary.
Inadequate lubrication of the master dies causing the pump to work harder than normal to reach the re-
quired diameter.
Inadequate pressure being generated by the pump. This is most likely if the crimper can crimp the smaller
size hoses and not the larger hoses. When correctly adjusted, the pump should generate approximately
5000 psi.
Do Not adjust pump to produce in excess of 5000 psi as damage to components or per-
sonal injury could result
No pressure being generated by the pump. There should be a defi nite change in pitch of the pump as it
cycles into high pressure mode and begins to "work" harder.
PROBLEM: CRIMP DIAMETER TOO SMALL
Check crimp diameter and recalibrate if necessary.
Incorrect die being used (See die range under Crimp Diameter Too Large).
Incorrect setting of the micrometer. Check hose manufacturer's specifi cations.