NOTE: If the recommended, optional BS Series backsplash is being installed, use
the template to locate and drill the appropriate holes for mounting. The back splash
must be installed before the hood canopy because the hood canopy will cover the
backsplash mounting screws. Refer to the instructions included with the backsplash
for complete installation instructions.
5. Rest the cavity in the back side of the hood on the wood strip and secure hood to
wood strip with the included 3/4" screws through the holes in the back of the hood
that line up with the wood strip (use 6 screws for 30" and 36" widths and 8 screws
for larger widths) Secure the bottom of the hood by installing the screws provided
into the wall anchors (Figure 12).
Wood
Mounting
Strip
Wall Anchor
Figure 12
6. From inside the hood canopy, secure hood to the underside of the cabinet by using
four wood screws (not included) through the keyhole slots of the hood (Figure 12).
CAUTION:
ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL
BUILDING CODES.
WARNING:
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
7. Determine the type of ducting you will require (Figure 13).
Horizontal
Wall Cap
Figure 13
NOTE: When determining the outlet adapter to be used, make sure to consider the
clearance within the cabinet space. Typically a horizontal Outlet Adapter will need to
be used if you will be venting out to a wall cap.
NOTE: When the duct termination is similar to that shown in Figure 13 (passing through
the wall to which the hood is mounted) the installation requires special consideration.
Depending upon where the wall studs are located, it may be necessary to cut one or
more of the wall studs and install a header and footer to transfer the load to the adjacent
studs. Additional studs may need to be framed into the opening to attach dry wall or
secure the hood. If this is your situation Air King recommends that you hire a professional
and comply with all applicable codes.
8. Install the proper sized outlet adapter (available separately) to the hood by sliding
it down into the hole cut earlier and matching up the four holes on the flange of
the adapter to the four corresponding holes on the hood and secure in place with
the provided screws. Ensure an airtight seal around the adapter by securing all
connections with ducting tape (Figure 14).
A111597016 Rev. B 3-10
Screw
Hood
Roof Cap
Outlet
Adapter
Outlet Adapter
Hood
Figure 14
9. Connect the ducting to the outlet adapter and damper. Secure in place using tape
to seal all joints (Figure 15).
Outlet Adapter
Hood
Figure 15
SECTION 7
Wiring
CAUTION:
DANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU
ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE
SERVICES OF A QUALIFIED ELECTRICIAN.
1. Remove the two wire compartment cover screws to
gain access into the wire compartment (Figure 16).
Connect the white wire from the range hood to the
white wire from the supply, and the black wire from
the range hood to the black wire of the supply.
Connect the ground wire from the home (green or
bare) to the ground wire (green) from the hood. Use
approved methods for all connections (Figure 17).
2. Replace the wire compartment cover and tighten
screws. Make sure all wiring is securely contained
within the wire compartment. If the quick connect
wire connector was removed from the receptacle,
replace. The connector will only fit one way into
the receptacle (Figure 16).
Vertical
Supply from house
Figure 17
www.airkinglimited.com
ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCOR-
Hot (Black)
Neutral
(White)
Ground (Green
or Bare)
Screw
Flange
Cabinet
Ducting
Damper
Wire Connector
Screws
Figure 16