Internal Earth and Isolation
The following table summarises the internal earth interconnection and isolation.
Please note that we use the term Earth-Ground to avoid international confusion. In Europe
Earth-Ground is called Earth; in the USA, Earth-Ground is called Ground.
Circuit
DMX512 Input
DMX512 Output
Internal Logic Ground

Application Diagram

The diagram below shows how railSplit uno could be utilised in a typical application.
railSplit uno User Guide
Type:
Pin 1:
Type:
Pin 1:
Connected to power supply 0V. If the selected PSU has a connection
between Earth-Ground and 0V the DMX outputs become Ground
Referenced. Otherwise the DMX outputs are Floating. When the
recommended PSU is used, DMX outputs are Floating.
Description
Isolated
Connects to internal isolated
circuit. No connection to
Internal Logic Ground
PSU referenced
Connected to Internal Logic
Ground