The Home Disaster
that detects flood and extreme temperature conditions.
Features
• Titanium probes for unmatched corrosion immunity
• Detects flood, freeze, and heat conditions
• Secure encrypted wireless transmissions
• 5-year warranty
Enroll
the flood sensor (ID ending in 0) by placing the
panel into wireless enrollment mode and then sending an
enrollment signal from the sensor.
Options for Sending an Enrollment Signal
• Remove the battery tab and cover to trip tamper
Freeze & heat inputs must be enabled as additional
zones to function. Activate only the zones needed in
order to extend battery life.
To activate and enroll a freeze input (ID ending in 1):
• Remove magnet from reed switch
• Hold down tamper and install battery
To activate and enroll a heat input (ID ending in 2):
• Have magnet next to reed switch
• Hold down tamper and install battery
Install
by placing the remote flood probe in the location
requiring flood or leak detection. If desired, the flood
probe can be screwed to the floor or baseboard. Next,
mount the sensor to the wall using the mounting screw
locations. Finally, connect the flood probe wires to the
sensor's terminal blocks.
Detects
water pooled under the sensor and reports extreme
temperature conditions.
Default Temperature Trip Points
• Heat alarms when over 100°F (38°C)
• Heat restores when under 97°F (36°C)
• Freeze alarms when under 45°F (7°C)
• Freeze restores when over 48°F (9°C)
RE319 Home Disaster
DSC
is an integrated environmental sensor
Use the panel installation guide to verify proper system setup.
Compatible
®
™
Mounting
Screw
Holes
Wire
Entry
Hole