Alula RE657WF-R 매뉴얼 - 페이지 8
{카테고리_이름} Alula RE657WF-R에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Alula RE657WF-R 12 페이지. Flat mount touchpad
• Users - manage device users directly from the touchpad (only the account owner can modify
users, internet access is required).
• Keypads - lists the panel's keypads
• Rename keypads by selecting an item on the list and holding it for 2 seconds
• Communication Test mode
• The Touchpad will begin testing communications and display "TESTING"
• After one minute, the Touchpad will show the result of the test which will be either
"GOOD," "FAIR," OR "POOR"
• If you get a "POOR" test result, try the test again from another location
• The table below lists the thresholds used to determine the outcome of the test
• If any statistic falls in the poor range, the test outcome is "POOR"
• If there are no poor statistics and any statistic is in the fair range, the outcome of the
test is "FAIR"
• If all statistics are in the good range, the outcome of the test is "GOOD"
Statistic
Wi-Fi Signal
Strength
Communication
Success Rate
Response Time
Average
• Check for updates - this will tell the panel to check for any system updates
• Z-Wave
• Join/Leave Another Z-Wave Network - the panel can be placed into Z-Wave inclusion or
exclusion mode to allow it to join/ leave existing Z-Wave networks.
• Soft Reset - a soft reset will reset the Z-Wave controller software. All Z-Wave devices will
remain enrolled.
• Hard Reset - this action will cause your Connect+ Z-Wave module to be restored back
to the default state. Warning: Performing this action results in all Z-Wave devices being
removed from this Z-Wave controller. To add them back, you will first need to exclude
them, and then include them again.
**PLEASE SEE Z-WAVE USER GUIDE FOR ADDITIONAL INFORMATION**
• About - lists information about the panel's installed hardware and software
Unit
GOOD
dB
Over 39
%
Over 89
ms
Under 200
FAIR
35 to 39
85 to 89
200 to 250
POOR
Under 35
Under 85