A8-ZIZA-TAPE
GENERAL FEATURES
Applications
Accent, Decorative, Surface, Recessed, Pendant Lighting
Viewing Angle
120°
Length
Built to Order (+/- 1/8" Tolerance)
Construction
Flexible LED Tape
Weight
0.016 lbs per foot
Mounting
Mounting Channel or Mounting Clips (Sold Separately)
Dry or Wet (IP67) Location
Listing
UL2108, CSA C22.2 #9
UL8750, CSA250
Driver
Remote (Sold Separately)
Temperature
Operating / Startup: -20° to 48°C (-4° to 120°F)
Ratings
Storage: -40° to 76°C (-40° to 170°F)
Installation Link
ELECTRICAL
Dimming
DMX
21' (5.5W)
Maximum Run
26' (4.5W)
(Class 1 Applications)
17' (5.5W)
Maximum Run
21' (4.5W)
(Class 2 Applications)
Luminaire Voltage
24V DC
PRODUCT INFORMATION
• For accent, decorative, surface, recessed, or pendant lighting.
• 24 Volts DC for easy and safe installation.
• Long life, energy effi cient LEDs.
• Can be ordered to specifi c lengths for when exact dimensions are known
Example: 10 x 10'6"
• Plug and light system.
• Lead wires are typically 36" long and exit on one end.
READ ENTIRE GUIDE BEFORE STARTING INSTALLATION
END VIEWS / DIMENSIONS
.09"
Dry Location
(All Wattages)
ELECTRICAL REQUIREMENTS
• Luminaires require a 24 Volt DC remote driver.
• To calculate driver size, determine Watts per Foot.
• Determine Length in Feet.
• Calculate Load: Multiply Watts per Foot x Length in Feet
• Choose a driver from catalog.
• Determine maximum driver distance using Maximum Wire Length Table on
INSTALLATION RECOMMENDATIONS
• Luminaires must be mechanically attached directly to mounting surface using
• Conduit raceway should be sleeved at one end for low voltage wires going to
INSTALLATION TOOLS REQUIRED
• Electric Hammer Drill
• 14.4 to 28 Volt Cordless Drill
• Phillips Bits
• Utility Knife
• Electrical Cord
• Marker
• Wire Stripper
ALUZ
1170 North Red Gum Street, Anaheim, CA 92806
Phone: 800 921 2254 or 714 535 7900 | Fax: 714 535 7902 | [email protected] | aluz.lighting
© ALUZ All rights reserved. ALUZ reserves the right to make changes or withdraw specifi cations without prior notice.
Important Notice: Verify correct luminaire was received with correct
color temperature, voltage, and wattage before cutting or installing.
ALUZ will not be responsible if incorrect luminaire is installed.
.46"
.36"
Wet Location
(4.5W)
Example: 4.5W per Foot
Example: 10'
Example: 4.5W x 10'= 45W
Example: 60 Watt Driver
drivers page.
Example: 45 watts is between 40W and 60W. Using #14 wire, maximum distance
is 37' from driver to fi rst LED.
mounting clips, channels, or other appropriate means. Refer to installation step
by step pages for details.
driver.
Installation Instructions
9 / 1 / 2021 / Rev 0
Page 1 of 11
Overview
.75"
.78"
.47"
Wet Location
(5.5W)
• Long Nose Pliers
• Drill Bits - Concrete or Wood
• Electrical Three Ways
• Safety Glasses
• Measuring Tape
• Laser Line or Chalk Line