METHOD OF ASSEMBLY.
1. Before screwing the stem pipe (F) into the cradle (B), check if the sealing
washer (E) is in position.
2. Screw the stem pipe into the cradle. Secure properly.
3. Clean the cylinder valve by blowing out or brushing with a small paint brush.
Failure to do this may result in the blockages in the jets.
4. Screw the stem/cradle assembly into the cylinder, ensuring a gas tight seal.
5. Place the cylinder on a at sturdy surface.
6. Place the cast iron top on the cradle upright and brush the side of the cast iron
plate you wish to use lightly with the cooking oil of your choice.
7. Perform a "Leak test" as speci ed below.
8. (Always light the cast iron plate (A) in position).
Strike a match, open the cylinder valve slightly and light one of the 3 burners.
The 2 remaining burners will ignite within 5 seconds.
9. If one or both of the burners do not ignite within 5 seconds, inspect burner jets
for blockages. Repeat procedure.
If the problem persists contact your dealer for assistance.
Once all 3 burners are alight, open cylinder valve to medium setting.
An even roaring sound will be heard - this is normal.
HOW TO CHECK FOR LEAKS.
Open the gas control at the cylinder and ignite the hotwheel.
Using a 50/50 water/soap solution, wipe or spray over the connection at
the top (G) and at the top (E) of the stem pipe (F).
If bubbles form on the connection/joint, then there is a leak.
Turn o the gas supply at the cylinder.
Tighten again and redo the leak test described above.
If the leak persists, replace the sealing washers.
If the leak persists, contact your local gas dealer to check.
NEVER USE A OPEN FLAME TO TEST FOR LEAKS.