Installing the Directional Adapter Bracket

Alvarado's default configuration for the CFG, CSG, and SSG gates is bi-directional (without the directional adapter
bracket installed). To configure a left- or right-hand only swing, install the directional adapter bracket per the
instructions below:
14. Swing the gate to the open position.
15. Using a 3/16" Allen wrench and (2) socket head cap screws, secure the directional adapter bracket to the lower
hinge post according to the desired swing direction [Figure 8].
16. Insert the first 1/4" flat point set screw and tighten it with an 1/8" Allen wrench until the flat point of the set screw
protrudes out of the opposite side of the adapter bracket. Swing the gate into the 'closed' position and adjust the
set screw until the gate is in proper visual alignment. Once the 'closed' position is properly aligned, insert the
second set screw and tighten it until it's stopped by the first set screw [Figure 8].
Fig. 8
Fig. 8
Left-Hand /Right-Hand Swing Configurations

Adjusting the Swing Limit

The swing limit set screw can be used to limit the gate
arm's degree of travel and/or prevent overtravel.
Use an 1/8" Allen wrench to adjust the set screw
[Figure 10]:
Turn the set screw counter-clockwise to decrease
the gate arm's degree of travel.
Turn the set screw clockwise to increase the
degree of travel (to maximum).
Page 6
PUD3570R2-0
CSG/SSG/CFG Installation and Maintenance Instructions
1.
Directional Adapter Bracket
2.
Flat Point Set Screws
3.
Socket Head Cap Screws
For Assistance: [email protected] (909) 591-8431
Fig. 10
Fig. 10
Adjusting the Swing Limit
Swing Limit Set Screw
Created on: 10/7/2013
©Alvarado Mfg. Co., Inc.