Operating Instructions And Parts Manual
Operation
2. With the cover uninstalled, add
water to the basin and observe the
float control switch operation.
Always disconnect the power
3. Also, test alarm switch if installed.
source before attempting to
4. Secure and seal basin cover.
install, service, relocate or
maintain the pump. Never touch sump
pump, pump motor, water or discharge
piping when pump is connected to
Do not run your pump in a dry sump.
electrical power. Never handle a pump
or pump motor with wet hands or when
standing on wet or damp surface or in
Do not attempt to oil the motor. A special
water. Fatal electrical shock could occur.
oil has been put in the motor housing at
1. Verify pump and switch operate
the factory. Use of any other oil could
damage the pump and WILL void the
within the basin.
warranty.
Maintenance
Risk of electrical shock! This pump is
supplied with a grounding conductor
and grounding type attachment plug.
Use a grounded receptacle to reduce
Always disconnect the electrical
the risk of fatal electrical shock.
supply before attempting to install,
service, relocate or perform any
Never cut off the round grounding
maintenance. If the power source is out
prong. Cutting the cord or plug will
of sight, lock and tag in the open (off)
void the warranty and make the pump
position to prevent unexpected power
inoperable.
application. Failure to do so could
result in fatal electrical shock. Only
qualified electricians should repair this
unit. Improper repair could result in
fatal electrical shock.
High Water Level
120º
Low Water Level
Figure 5 - Simplex System
www.blueangelpumps.com
1. Let the pump cool for a minimum of
two hours before servicing because
the pump contains hot oil under
pressure and the motor is hot.
2. Disassembly of the motor prior to
expiration of warranty will void the
warranty. If repairs are required,
see troubleshooting chart.
3. Inlet should be kept clean and free
of all foreign objects and inspect
annually. A clogged inlet will
damage pump.
4. Pump should be checked monthly
for proper operation.
This pump contains dielectric oil for
cooling. This oil can be harmful to the
environment. Check the state
environmental laws before disposing
this oil.
Pump #1
Pump #2
Discharge
Discharge
On Level
Alarm Level
Off Level
Figure 6 - Duplex System
4
Operating Instructions And Parts Manual
Troubleshooting Chart
Symptom
Possible Cause(s)
Pump will not start or
1. Blown fuse
run
2. Low line voltage
3. Defective motor
4. Defective float switch
5. Impeller
6. Float obstructed
Pump starts and stops
1. Backflow of water from
too often
piping
2. Faulty float switch
Pump will not shut
1. Defective float switch
off or thermal
2. Obstacle in piping
protector turns off
3. Float obstructed
4. Low Line Voltage
5. Too many appliances on
circuit
Pump operates but
1. Plugged impeller
delivers little or no
2. Check valve installed
water
backwards
3. Pump airlocked
Corrective Action
1. If blown, replace with proper sized fuse or reset breaker
2. If voltage is under 108 volts, check wiring size
3. Replace pump
4. Replace float switch
5. If impeller will not turn, remove housing and remove
blockage
6. Make sure float(s) move freely up and down
1. Install or replace check valve
2. Replace float switch
1. Replace float switch
2. Remove pump and clean pump and piping
3. Make sure float move freely up and down
4. If voltage is under 108 volts, check wiring size
5. Install pump on dedicated circuit. IMPORTANT: Do not use
extension cord to power pump.
1. Clean out impeller
2. Reverse position of check valve
3. Check the 1/8" hole in discharge line between pump and
check valve; it should be 1" to 2" above discharge flange and
before the check valve
www.blueangelpumps.com