Et BLUE-ROLL 설치 매뉴얼 - 페이지 9

{카테고리_이름} Et BLUE-ROLL에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Et BLUE-ROLL 17 페이지. Domestic type roll-up garage door operator

A
B
C
Receiver programming and detect LED
D
E
F
G
H
I
Battery low monitoring beep tone jumper
1.
N/O Safety beams input (BM)
2.
N/O Courtesy light input (L)
3.
Common output (C)
4.
N/O Button trigger input (BT)
5.
Green 0,3mm from motor head lead -
6.
White 0,3mm from motor head lead -
7.
Brown 0,3mm from motor head lead -
8.
WHITE -
9.
WHITE -
10. GREEN & YELLOW -
11. GREEN & YELLOW -
12. BLUE -
13. BROWN -
14. BROWN -
15. BROWN -
16. Per Opener mounting -
17. Per opener mounting -
18. BLUE -
19. RED -
20. YELLOW -
21. YELLOW -
22. Positive auxiliary output (+ 12V, 100mA peak )
23. 0V auxiliary output (Ground)
Autoclose jumper
Receiver programming pins
Onboard test button
220Vac mains fuse
Load POT
Charger float voltage POT
Motor power supply fuse.
The colouring of the factory fitted wiring is highlighted here
On = active (20secs and pre-beep warning)
BT + centre = Button trigger function (25 users)
LT + centre = Courtesy light function (6 users)
See table under receiver programming section below
Replace with 2A fast blow type only
Increase (Anti-clockwise) or Decrease (Clockwise)
allowed resistance before safety reverse intitiates.
Adjust for closing cycle. Open cycle is automatically
This is preset in the factory to 27.2Vdc.
Replace with 8A fast blow type fuse only.
If this fuse is blown the entire control card will be
On = Battery low beeps de-activated.
Off = Battery low beeps active. (Must be off when
For further detail on these features see page 11
N/C Closed limit input (LC)
Limit switch common output (C)
N/C Open limit input (LO)
220Vac Courtesy light output (LMP)
220Vac Courtesy light output (LMP)
Motor and transformer earth (E)
Household earth (E)
220Vac Neutral input (N)
220Vac Live input (L)
220Vac output to transformer primary (PRI)
220Vac output to transformer primary (PRI)
24Vdc motor output (MOT)
24Vdc motor output (MOT)
Battery negative (BAT)
Battery positive (+)
24Vac input from transformer secondary (SEC)
24Vac input from transformer secondary (SEC)
Fig. 11
Functions as per transmitter BT
set.
Peak current 370mA.
without power.
batteries are installed)
9