Rain Bird® ESP Modular (6 Pin)
PREPARING YOUR RAIN BIRD CONTROLLER:
1. Turn the selector knob to "OFF."
2. Power off the controller.
ATTACHING THE HERMITCRAB COMMUNICATIONS
CABLE:
1. Connect the 6 Pin plug on the communications cable to
the "remote" connector on the back of the host controller's
front panel.
2. Connect the red and black wires to the AC power
output terminals. Either wire can connect to either terminal
Rain Bird® STPi and SST Series (5 Pin)
PREPARING YOUR RAIN BIRD CONTROLLER:
1. Turn the selector knob on your Rain Bird controller
to select station "1" and press the "ZONE OFF" button.
Repeat for all stations in use.
2. Turn the selector knob to "AUTO."
3. Power off the controller.
ATTACHING THE HERMITCRAB COMMUNICATIONS
CABLE:
1. Remove the factory two-pronged 24VAC connector
from its connection on the Rain Bird.
2. Attach the separate black wire on the HermitCrab
communications cable to the 24 VAC connector on the left
side of the host controller.
3. Plug the HermitCrab controller 5 Pin communications
cable into the accessory plug on the right side of the host
controller.
4. Reconnect the factory 24VAC connector.
Page 14
HermitCrab
Red and black
communications cable
wires attached
attached to Rain Bird
to "24 VAC"
remote connector
terminals
"24 VAC"
Black wire
HermitCrab
connector
attached to "24
communications
VAC" prongs
cable
Rain Bird® ESP-ME (5 Pin with fly
wire cable )
PREPARING YOUR RAIN BIRD CONTROLLER:
1. Turn the selector knob to "OFF."
2. Power off the controller. Never attach the HermitCrab to a
powered host controller.
ATTACHING THE HERMITCRAB COMMUNICATIONS
CABLE:
1. Connect the 5 Pin socket on the communications cable
to the "remote" port on the back of the host controller's front
panel.
2. Connect the black wire to the AC power output terminal.
3. Power the on the Host controller and begin setting up the
HermitCrab.
Rain Master® Sentar™, Eagle, Hawk,
and Evolution™ DX2
PREPARING YOUR RAIN MASTER HOST CONTROLLER:
1. Power off the controller.
ATTACHING THE HERMITCRAB COMMUNICATIONS
CABLE:
1. Plug the HermitCrab controller
communications cable into the remote connector on the
upper left hand side of the front panel.
NOTE: All Rain Master Controllers will display the word
"REMOTE" once they are powered on with the
HermitCrab controller attached.
5 pin Socket
Black wire connected
connector in
to AC terminal
remote port
HermitCrab communications cable attached
to Rainmaster remote connector