AKOS Gemini M 설치 매뉴얼 - 페이지 16

{카테고리_이름} AKOS Gemini M에 대한 설치 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. AKOS Gemini M 20 페이지. Insert fireplace

Sample calculation 2
Count the horizontal lengths
Flue pipe lengths: J + L = 0,5 + 0,5=1 m
Bends: K+ M = 2 + 2 m = 4 m
Wall terminal: 1 m
Total horizontal length: 6 m
Count the vertical lengths
Flue pipe length H
Total

8 Deflector State Table

− Find the correct vertical and horizontal lengths in the table.
− In case of an "x", or if the values are outside the table, the combination is not permitted. The
value found indicates the deflector indicator ("0" meaning that the deflector is completely
open).
AKOS Sp. z o o.
ul. Bruszewska 22, 03-046 Warszawa
NIP: 5361925006; REGON 365653140
Tel: +48881697975; email: [email protected]
1 m
1m
Horizontal
0
1
2
10
13
13
10
9
13
12
10
8
13
12
10
7
11
11
9
6
10
11
9
5
9
10
8
4
8
10
8
3
7
8
7
2
7
6
5
1
6
3
2
3
4
5
6
9
6
3
7
9
5
3
7
8
6
4
6
6
5
4
5
6
6
4
5
6
4
2
4
6
4
2
3
6
5
4
2
4
3
2
1
1
0
0
0
7
8
6
5
6
4
5
4
4
3
3
3
2
2
0
2
0
0
0
X
X
X
16 <
<
<
<