COMMUNICATION & CONTROL
MULTICONDUCTOR, UNSHIELDED
PVC/PVC
C
HARACTERISTICS
OPERATING TEMPERATURE:
I
–20°C to 80°C – AWM
I
75°C – CM
VOLTAGE RATING:
I
300 Volt – CM
I
150 Volt – CL2
COLOR DESCRIPTION:
I
182
Color Code: Chart D Page 375
I
Jacket Color: Gray
PRODUCT DESCRIPTION:
I
Conductor: Stranded Tinned Copper
I
Insulation: Color-Coded PVC
I
Jacket: PVC
S
PECIFICATIONS
I
UL Type CM, AWM 2509 (18 & 16 AWG)
I
UL Type CL2, (14 & 12 AWG)
I
CSA CMG FT4 (18 & 16 AWG)
I
CSA AWM
A/B,
I
I
Passes UL Vertical Tray Flame Test
I
"C" Suffix Indicates CM or CL2 Rating as Applicable
I
RoHS Compliant
®
A
VAILABILITY
I
100 ft (30,5m), 500 ft (152m),
1000 ft (305m) put-ups
Toll Free: 1-800-52 ALPHA • Telephone: 908-925-8000 • Fax: 908-925-6923
Europe/UK Telephone: +44 (0) 1932 772422 • Europe/UK Fax: +44 (0) 1932 772433
A/B FT4 (14 & 12 AWG)
II
80°C 300V - UL 2509 - NEC TYPE CM
18 AWG
16/30
(0,81mm
2
),
(16x0,25mm), Insulation Thickness:
Alpha
No. of
Part No.
Cond.
1897C
2
1898C
3
1898/4C
4
1898/5C
5
1898/6C
6
1898/7C
7
1898/8C
8
1898/9C
9
1898/10C
10
1898/12C
12
1898/15C
15
1898/19C
19
1898/25C
25
80°C 300V - UL 2509 - TYPE CM
16 AWG
19/0.0117
(1,31mm
2
),
Alpha
No. of
Part No.
Cond.
1899C
2
1899/3C
3
1899/4C
4
80°C 300V - UL TYPE CL2
14 AWG
41/30
(2,08mm
2
),
(41x0,25mm), Insulation Thickness:
Alpha
No. of
Part No.
Cond.
1891C
2
1891/3C
3
80°C 300V - UL TYPE CL2
12 AWG
65/30
2
(3,31mm
),
(65x0,25mm), Insulation Thickness:
Alpha
No. of
Part No.
Cond.
1892C
2
1892/3C
3
UL TYPE CM
UL AWM 2509, CSA CMG FT 4
RoHS COMPLIANT, 300 VOLT
0.016"
Jacket Thickness
Diameter
Inches
mm
Inches
0.020
0,50
0.20
0.020
0,50
0.21
0.020
0,50
0.24
0.020
0,50
0.26
0.020
0,50
0.29
0.020
0,50
0.29
0.025
0,63
0.31
0.025
0,63
0.34
0.025
0,63
0.37
0.025
0,63
0.38
0.030
0,76
0.44
0.030
0,76
0.47
0.035
0,88
0.56
0.016"
(19x0,29mm), Insulation Thickness:
Jacket Thickness
Diameter
Inches
mm
Inches
0.020
0,50
0.22
0.020
0,50
0.24
0.020
0,50
0.27
0.020"
Jacket Thickness
Diameter
Inches
mm
Inches
0.020
0,50
0.26
0.020
0,50
0.28
0.020"
Jacket Thickness
Diameter
Inches
mm
Inches
0.020
0,50
0.30
0.020
0,50
0.32
Web Site: www.alphawire.com
Email: [email protected]
(0,41mm)
mm
5,0
5,3
6,1
6,6
7,4
7,4
8,0
8,8
9,4
9,8
11,3
11,9
14,1
(0,41mm)
mm
5,7
6,3
6,9
(0,50mm)
mm
6,6
7,1
(0,50mm)
mm
7,6
8,1