Clinton A300 Series 사용자 설명서 및 사용 설명서 - 페이지 12

{카테고리_이름} Clinton A300 Series에 대한 사용자 설명서 및 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Clinton A300 Series 16 페이지. 2 cycle engine

TROUBLE SHOOTING CHART
TROUBLE
PROBABLE CAUSE
1.
ENGINE FAILS
No fuel in tank.
TO START
Fuel shut-off valve closed
Sediment in carburetor
Air lock in fuel line
Fuel line clogged
Broken high-tension lead
Reed valve not seating
2. ENGINE HARD
Water in fuel
TO START
Loose or defective wiring
Defective reed valve
Spark plug cracked
Spark plug fouled
Dirty or corroded breaker pts.
Poor compression resulting
from:
Loose spark plug
Defective reed valve
Worn rings
3.
ENGINE
Spark plug fouled
MISSING
Spark plug cracked
Improper spark plug gap
Shorted high tension lead
Magneto or condenser
terminal loose
Dirty or corroded breaker pts.
Water in fuel
4. ENGINE
Carburetor choke partly
OVERHEATING
closed
Air flow obstructed
Insufficient lubrication
12
REMEDY
Fill Tank
Open Valve
Drain carburetor bowl
Bleed fuel line
Clean out the line
Replace lead
Contact nearest Clinton Service Station
Drain and refill entire fuel system.
There may be ice in cold weather
Check high-tension lead for breaks or
loose connections
Contact nearest Clinton Service Station
Replace plug
Clean plug; reset gap to .025
Clean or replace; reset points to .018
or .020 inch
Tighten
plu-g
Contact nearest Clinton Service Station
Contact nearest Clinton Service Station
Clean plug; reset gap to .025
Replace plug
Reset to .025
Replace lead
Tighten terminals
Clean or replace and reset points to
.018 to .020 inch
Drain and refill entire fuel system
See that choke setting is wide open
Check to see that all air passages
around cylinder and head are free
from dirt and weeds. Clean flywheel
fins
Check for proper ratio of oil and gas
mixture in fuel tank