Dodge Quantis Ultra Kleen 사용 설명서 - 페이지 4

{카테고리_이름} Dodge Quantis Ultra Kleen에 대한 사용 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Dodge Quantis Ultra Kleen 8 페이지.

MOUNTING POSITION DIAGRAMS -
QUANTIS UK RHB REDUCER
These mounting arrangements are for all output configurations
and output shaft types.
IMPORTANT! When ordering, please specify mounting position
for correct oil quantity. In cases of mounting position other than
shown here with regard to the oil quantity, please reference the
Incline Mounting page in the Quantis Engineering Catalog, and
contact Application Engineering.
NOTE: The oil volumes shown are approximate values and cannot
be used to correctly set the reducer oil level - ALWAYS fill the
reducer to the correct oil level plug and recheck in 1 week.
Oil Level
B
A
A1 - Horizontal - Floor Mount
NOTE: Shaded A2 mounting is not a recommended mounting
position due to the weight of oil on the highspeed input seal.
A2 - Vertical Wall Mount - Motor Shaft Up
A
B
A3 - Horizontal - Ceiling Mount
Ventilation
Oil Drain
A
B
A4 - Vertical Wall Mount - Motor Shaft Down
B
B
A
A5 - Horizontal - Wall Mount
A6 - Horizontal - Wall Mount
4
A
A
B
MN16022