DOEPFER A-143-2 매뉴얼 - 페이지 2

{카테고리_이름} DOEPFER A-143-2에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. DOEPFER A-143-2 6 페이지. System a-100, quad adsr

DOEPFER A-143-2 매뉴얼
Quad ADSR A-143-2

2. Basic Principles

Fig. 2 shows the basic function of each unit:
Fig. 2: Basic function
The positive edge of the gate input starts the envelope
signal and resets both the "End of Attack (EOA)" and "End
of Release (EOR)" output. The time required to reach the
maximum value of the envelope is defined by the attack
control. As soon as the envelope level reaches the sustain
level during the rising slope, the digital "End of Decay
(EOD)" output turns low. As the maximum value (about +8
V) is reached, the EOA output turns "high" and the so-called
Decay phase begins. In the decay phase the slope falls to
2
System A-100
the Sustain level defined by the sustain control with a time
adjusted by the decay control. At the end of the decay
phase the envelope output remains at the sustain level until
the gate signal turns low. When the gate signal turns low the
EOD output turns high and the Release phase of the
envelope begins. The slope falls to zero with a time adjusted
by the release control. When the envelope level reaches
about +0.5V the EOR output turns high.
The retrigger behaviour of the A-143-2 is different compared
to other envelope generators. During the attack phase the
envelope cannot be retriggered or reset. During the decay
phase the envelope direction changes if a positive edge
appears at the retrigger input (i.e. the envelope changes
from decay to attack state).
Fig. 3: Retrigger behaviour
DOEPFER
DOEPFER
DOEPFER
DOEPFER