Acqua Brevetti FT120 설치 및 운영 매뉴얼 - 페이지 8

{카테고리_이름} Acqua Brevetti FT120에 대한 설치 및 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Acqua Brevetti FT120 9 페이지.

MAN055 – REV. 0 DATE: 11.01.2011

5.1.5 Troubleshooting

Problem
High head losses across the
filtering cartridge
Water draw from discharge
valve
Increase
of
the
pressure
downstream
the
pressure
reducer in the presence of a
boiler
The pressure reducer do not
maintain the pressure set
Water leakage from the upper
part of the pressure reducer
Attention
This kind of operations must be done by qualified technical personnel
Acqua Brevetti 95 s.r.l.
DRAFT BY: U.T.
Cause
Dirty filtering cartridge
Discharge valve not completely
closed (dirt in the o-ring seat)
Filter out of phase
Water overheating, increase of
water volume.
Foreign bodies in the shutter
gasket
Pressure
reducer
membrane
damaged
Solution
Activate back wash
See paragraph 5.1.6 "Discharge valve cleaning".
See paragraph 5.1.5 "Placing the filter in phase"
Install an expansion tank.
Open the pressure reducer and clean the
gasket. Check the filter which is probably not
properly working.
Replace the membrane.
PAG. 8 DI 9