{카테고리_이름} Cygnus electronics ER-601A에 대한 빠른 시작 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Cygnus electronics ER-601A 2 페이지. Electric lock
B.f you want to connect the negative side to open the lock, please connect the contact"+"
and "L + 12 v" with a short wires, otherwise it cannot control the lock;(Please check the
wiring diagram --B )
4. Install the base late: Connect the lock to the power supply, fix the base late with screw;
C.Check the circuit board by connecting the power(DC12-18V)
Make sure:
1,close the door,the bolt will be out automatically
2,Input the door signal--OPEN (From the building intercom or Access control system),the
bolt will hold back then the door will open,and after several minutes,the lock will close
again.
3, Repeat the step-- 1, 2 confirm if the space between the bolt and bolt ensure the
operation of lock.
D.FAQ
1、Close the door,but the lock don't lock.
A,Check the power supply and the wiring.
B.Check the reed switch,confirm if it is the broken.
C.Check the space between the bolt and bolt,the Proper distance is 5~10mm.
D,Check the installing position of the lock.
2、Input the signal--Open,but the lock don't open.
A,Check the wiring of the access control system.
3、Manually opening the lock is not flexible
A.Check the connection head of plug,confirm it is stuck,make sure there is no foreign
matter in the lock.
E.Notice
1,In case of damage the lock,we cannot install the lock by welding.
2,Development about the lock will be made without any notice.Any detail,please refers to
the new version.
3.The lock is not used for the fire alarm system.It is forbidden to install the lock to the fire
door,otherwise the consequence is proud.Any damage by wedding during the
installation,We won't repair it.