ASG BLG-5000BC2 운영 매뉴얼 - 페이지 5

{카테고리_이름} ASG BLG-5000BC2에 대한 운영 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ASG BLG-5000BC2 7 페이지. With built in screw counter, with built in screw counter and pulse system, for use with screw counter

BLG-BC1 Features
Brushless screwdriver with built-in screw counter
OPC (output signals) is available.
When the screwdriver is connected to the HIOS relay box "BLOP-
AF", an external device such as a sequencer, a revolving light or
a buzzer can be used to visualize the screw fastening operation
with the signals.
This unit can be used also as a normal screwdriver with the
counting function canceled. The display is also OFF.
The screwdriver, running without fastening the screw, or reverse
turning, is not counted.
Screw fastening errors can be detected with easy operation and
setting.
Counter Display Section
6
7
8
5
Screw Fastening Count Display Section/Set Value Display Section
In the normal mode, the screw fastening count set
value is displayed first, and after starting the count, the
remaining screw fastening count is displayed. The count
decreases with each screw fastening operation and the
remaining screw fastening count is displayed.
Function Display Section
The symbol corresponding to the set item is displayed in
the setting mode.
F1 Button
When this button is pressed for more than 2 second in
the normal mode, the mode is changed to the setting
mode. This button is used for selecting the function in the
setting mode. When this button is pressed for more than 2
seconds in the setting mode, the buzzer sounds twice and
the mode is changed to the normal mode.
F2, F3 Button
Using these buttons, the set value can be changed in the
function setting. Some set values are limited depending on
the function to be set.
Pass Light*
When the screw fastening result is "OK", the green LED
light turns ON.
Fail Light*
When the screw fastening result is "NG", the red LED light
turns ON.
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
HIOS BLG-BC1 Series
Operational Manual
1
Function Display
1
Section
2
Screw Fastening,
Count Display Section,
2
and Function Display
Section
3
M Light
4
Pass Light
Fail Light
5
F1 Button
3
6
4
7
F2 Button
F3 Button
8
| Phone: (
44110-3898
888) 486-6163
Other Operations
The count is to be returned to the default value during the screw
fastening operation.
Pressing the F3 Button for 2 seconds or more, resets the screw
fastening count value.
How to check the Counter Timer Set Time
When the screw is fastened for the time period (second) set
using the counter timer: For correct operation, the buzzer
sounds once. For incorrect operation, the buzzer does not
sound. When the buzzer does not sound, increase the set
value gradually and adjusts it so that the buzzer sounds
once. The confirmation with the buzzer sound is useful for
preventing a screw fastening error.
Lock F Buttons
Slide the FOR/REV switch to FOR. Idle for about 20 seconds.
M Light is turned on, and the buttons are locked. They will be
unlocked if you redo the steps.
| Fax: (
| Email: [email protected] | Web: www.asg-jergens.com
216) 481-4519