ASG TLB-D419L 매뉴얼 - 페이지 3
{카테고리_이름} ASG TLB-D419L에 대한 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. ASG TLB-D419L 9 페이지. Tlb-d series. brushless electric screwdrivers
Safety Instructions
•
Make sure the switch is in the OFF position and tool is unplugged when changing
a bit
•
Do not allow chemicals such as acetone, benzene, thinner, trichloroethylene
ketone, or other similar chemicals to come in contact with the screwdriver housing
as damage will result.
•
Do not drop or misuse the screwdriver.
•
Do not adjust the torque setting higher than 8 on the torque scale.
•
There should be a tool rest interval for cycles of three seconds or longer. This tool
is intended for a duty cycle of 0.8 seconds on, 3.2 seconds off.
•
Do not tighten more than 800 tapping screws (size: 3mm. Length: 5mm) per hour.
•
Do not use this screwdriver for tightening wood screws.
•
Do not operate the Forward/Reverse Switch while the motor is running.
•
Turn the switch to the OFF position and unplug the screwdriver when the tool is
not in use
•
Always grasp the plug of the power cord when plugging in/unplugging.
•
Always secure the power supply to avoid movement.
•
If the power supply overheats or is overloaded with maximum current rating, the
high-speed fuse will cut off the power. If this situation continues, stop operation
immediately and contact ASG for repair.
•
Do not disassemble the electric screwdriver or try to repair it yourself.
•
When power supply is not in use, please turn the main power switch OFF and
unplug the power supply.
ASG, Division of Jergens, Inc.
S. Waterloo Road | Cleveland, OH
15700
44110-3898
| Phone: (
| Fax: (
| Email: [email protected] | Web: www.asg-jergens.com | Revision Date: 01/03/18
888) 486-6163
216) 481-4519
Description of Operation
Inserting/Removing Bit and Bit Type
•
Push up the holder clamp to unlock it. Thus, the bit can be freely attached and
detached.
•
Insert the power plug into a receptacle and set the switch to "F" (forward
position)
•
Apply the bit to the screw head and either press the lever or push to start the
tool. The switch will be turned ON to start the motor running.
•
When the screw is tightened and reaches the torque that you had set, the tool
will stop automatically.
•
To reverse the screw, set the changeover switch to "R" (reverse position).
Do not operate this tool without protective earth connected
Grounding Instructions
The tool should be grounded while in use to protect the operator from electric shock.
The tool is equipped with a three-conductor cord and three-prong grounding-type plug
to fit the proper grounding-type receptacle. The green (or green and yellow) conductor
in the cord is the grounding wire. Never connect the green (or green and yellow)
wire to a live terminal.
Green and Yellow
Blue
Brown
Earth
Neutral
Live
3