35-0699-99X01
Nuisance Odor Pad Assembly, 1/Case
35-0799-99X01
Nuisance Odor Pad, 1/case
35-0799-99X10
Nuisance Odor Pad, 10/case
15-0399-99X02
Organic Vapor/Acid Gas* Cartridge, 2/case
15-0399-99X06
Organic Vapor/Acid Gas* Cartridge, 6/case
15-0499-99X02
Organic Vapor/Acid Gas* Cartridge, 2/case
15-0499-99X06
Organic Vapor/Acid Gas* Cartridge, 6/case
15-0009-99X02
Spark Arrestor, 2/case
* Acid gas: NIOSH approved for sulfur dioxide, chlorine, hydrogen chloride
TROUBLESHOOTING
Use the table below to help identify possible causes and corrective action for problems you may experience. There are no
user serviceable parts inside the 3M™ Adflo™ PAPR Assembly. The motor/blower unit should not be opened to attempt
repairs. Consult the 3M™ Adflo™ PAPR Trouble Shooting Guide or contact 3M Technical Service to help identify additional
possible causes and corrective actions for other problems you may experience.
Fault
Probable Cause(s)
Low air flow alarm (audible
1. Breathing tube is blocked.
and all three LEDs on
2. Filter is blocked.
power button are lit)
3. Filter is fully loaded with
particles.
4. PAPR is being used above
recommended altitude
limitation.
Bottom bar of battery
Low battery voltage.
indicator flashes; battery
alarm sounds
No air flow, no alarm(s)
1. Battery contact on battery
pack is damaged.
2. Battery is completely
discharged.
3. Damaged circuit board.
4. Damaged motor.
Low air flow per indicator
1. Damaged circuit board.
but no alarm(s)
2. Damaged motor.
User detects odor or taste
1. Incorrect respirator
of contaminants or feels
for application and/or
eye or throat irritation
environment.
2. Chemical cartridge exhausted.
3. Nuisance odor pad.
4. Particle filter damaged.
Battery pack's charge lasts
1. Inadequate charging.
less than expected
2. HE filter is loaded with
particles, making the motor
run harder.
3. Chemical cartridge being
used.
4. Motor blower is being used at
high elevations.
The motor runs "faster than
1. The HE filter is loaded with
normal"
particles.
2. Recent user change from just
HE filter to HE and Nuisance
Odor Pad Assembly or HE and
OV/AG cartridge.
The motor runs "slower
1. Recent user change from
than normal"
HE and Nuisance Odor Pad
Assembly or HE filter and
OV/SD/CL/HC cartridge to just
the HE filter.
Possible Solution(s)
1. Check & remove blockage or obstruction.
2. Check air filter & remove obstruction.
3. Change HE filter and pre-filter. If using a
chemical cartridge, check that the scrim
fabric behind the inlet holes is clean and
white. Any sign of particle loading on the
chemical cartridge indicates improper
installation or damaged particle filter
assembly.
4. Consider 3M™ High Altitude Compensation
Adflo™ PAPR or an alternative 3M™ PAPR.
1. Fully charge the battery pack.
2. Install a new, fully-charged 3M™ Adflo™
PAPR Battery Pack.
1. Check that the battery contact is not bent or
broken.
2. Fully charge the battery pack.
3 and 4. Contact 3M Warranty and Repair.
Contact 3M Warranty and Repair.
1. Consult on-site industrial hygienist or safety
director.
2. Change cartridge & develop a cartridge
replacement schedule with your on-site
industrial hygienist or safety director.
3. Replace nuisance odor pad.
4. Replace particle filter.
1. Check the filter-loading indicator.
2. Replace the HE filter & pre-filter as indicated,
and examine the spark arrestor.
3. Battery pack will normally have shorter run
time with chemical cartridge in place.
4. Consider 3M™ High Altitude Compensation
Adflo™ PAPR or an alternative 3M™ PAPR.
1. Check the filter-loading indicator. Replace
the HE filter & pre-filter as indicated, and
examine the spark arrestor.
2. Normal operation. Let the unit run for 2
minutes so it can automatically adjust to new
configuration.
1. Normal operation. Let the unit run for 2
minutes so it can automatically adjust to the
new filter configuration.
Fig. 2
Fig. 1
1- Cover; 2 - Spark Arrestor; 3-Pre-filter; 4 - HE Filter
1- Protège-filtre; 2- Pare-étincelles; 3- Préfiltre;
4- Filtre à haute efficacité
Fig. 4
Fig. 5
Fig. 7
Fig. 8
Fig. 9A
Fig. 10
Fig. 13
Fig. 12
Fig. 3
Fig. 6
Fig. 9
Fig. 11
Fig. 14