6. OPERATION CONTROLS AND FUNCTIONS

6.1 Front Panel

POWER
4K2K
+
1
2
1
POWER LED: This LED will illuminate when the device is connected
with power supply.
2
4K2K LED: This LED will illuminate when the input source contains
4K2K signal.
SYNC LED: This LED will illuminate when the input source is sending
3
signal.
4
MENU: Press this button to enter into OSD menu and when under
OSD selection press this button to exit. Press and hold this button
together with TEST PATTERN "-" button for 3 seconds to set the
device back to factory default.
5
TEST PATTERN -/+: Press these buttons to select patterns to display
on outputs instantly. Press these buttons together to switch output
timing to 1280x720@60 instantly. When under OSD selection, press
these buttons to roll the scroll.
6
ENTER: Press this button to enter and confirm OSD selection.
Press and hold this button together with the MENU button for
3 seconds to enter into firmware update mode. The LEDs will
illuminate in circle from left to right. Plug in the USB thumb drive
with updated firmware inside and the LEDs will stop illuminating.
Once the update procedure completed or successfully, all LEDs
will illuminate together but if update failed no LED will illuminate.
The device will automatically reboot after 10 seconds or user may
re-power on the device manually.