6.5.1 Keystone
Option
Projection
Application
Horizontal
Keystone
Vertical
Keystone
Anyplace
Location
Pincushion/
Barrel Demo
Rotation Demo
6.5.2 Anyplace
Option
Projection
Application
Horizontal
Keystone
Vertical
Keystone
Anyplace
Location
Pincushion/
Barrel Demo
Rotation Demo
Description
Keystone
-40~40 horizontal keystone adjustment, factory default
value is on 0
-30~30 vertical keystone adjustment, factory default value
is on 0
N / A
Display location selection: Front Tabletop/Front Ceiling/
Rear Tabletop/Rear Ceiling
-15~15 Pincushion/Barrel Demo adjustment, factory
default value is on 0
N / A
Description
Anyplace
N / A
N / A
To adjust the Horizontal/Vertical Keystone from Top Left or
Top Right, Bottom Left or Bottom Right, Reset Top Left or
Reset Top Right, Reset Bottom Left or Reset Bottom Right.
After selected the Horizontal/Vertical Keystone from Top
Left or Top Right, Bottom Left or Bottom Right selection
press up/down/left/right to adjust keystone angles. The
Horizontal Keystone ' s maximum steps is 576 and Vertical
Keystone ' s maximum steps is 324. When both Horizontal
and Vertical Keystone been adjusted at the same time
the Horizontal and Vertical Keystone steps will not meet
the maximum steps, the system will calculate and display
with the best ratio for Horizontal and Vertical Keystone
steps
Front Tabletop/Front Ceiling/Rear Tabletop/Rear Ceiling
N / A
N / A
7