Acquaer PEP033 소유자 매뉴얼 - 페이지 4

{카테고리_이름} Acquaer PEP033에 대한 소유자 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Acquaer PEP033 11 페이지. Pedestal pump
Acquaer PEP033에 대해서도 마찬가지입니다: 소유자 매뉴얼 (6 페이지)

Acquaer PEP033 소유자 매뉴얼
  4 .
  I t is highly recommended to install a full flow, swing type check valve (not included) as close to
the discharge outlet on the pump as possible. A new check valve will greatly increase the life of
your pump, and should be the same size as the pump discharge, 1 ¼" or 1 ½".
  C onnect the pump and check valve together using schedule 40 PVC pipe and fittings. You can
5.
also use DWV or ABS pipe, as this is not a pressure installation. Corrugated drain hose is
intended for temporary use and should not be used in a permanent installation. Although there
are many types of pipe that work adequately for this installation, PVC is recommended.
6.
  T est your installation after you have completed setting up the pump and connected all piping.
Plug the cord into the grounded outlet. The pump should not run at this point. If the pump runs,
the switch is stuck in the upright position. Fill the sump basin with water using buckets or a hose.
When the float moves to the upright position, the pump will turn on. The switch will turn off the
pump when the float reaches the down position. You may adjust the "turn on" position to meet
your particular needs by moving the grommet up or down on the float rod. Remember the switch
must move up and down freely without touching the sides of the sump basin.
Problem
1.
Pump is not plugged in, switch or
breaker is off
the pump
2.
Check for blown fuses or tripped
does not
circuit breakers or tripped GFCI
start or run
outlets
3.
Switch is defective
4.
Motor thermal protector tripped
5.
Float ball is stuck or obstructed
The pump
1.
Backflow of water from discharge
starts and
hose/pipe
stops too
2.
Switch is defective
often
1.
Clogged intake screen
2.
Clogged discharge hose/pipe
3.
Frozen discharge hose/pipe
If the pump
4.
Low line voltage
runs but
5.
Check valve is stuck in the closed
moves little
position
or no water
6.
Check valve is installed backwards
7.
Worn, damaged or clogged pump
parts
Pump does
1.
Float ball is obstructed or stuck
not shut off
2.
Defective Switch
INSTALLATION INSTRUCTIONS

TROUBLESHOOTING

Possible Cause
Corrective Action
1.
Plug pump in or turn on switch
/breaker
2.
Replace fuse, reset breaker, reset
GFCI outlet
3.
Replace fuse, reset breaker, reset
GFCI outlet
4.
Allow pump to cool. Pump will reset
5.
Remove obstruction or position
pump so it will not become stuck
1.
Install or replace check valve
2.
Replace switch
1.
Clean or replace screen
2.
Remove clog
3.
Allow hose/pipe to thaw
4.
Check wire size and increase if
necessary
5.
Inspect, repair or replace if
necessary
6.
Inspect, repair or replace if
necessary
7.
Inspect for wear, damage or clog
and clean or replace if necessary
1.
Remove obstruction
2.
Replace switch