Close Comfort EASY FOCUS 사용자 설명서 - 페이지 4
{카테고리_이름} Close Comfort EASY FOCUS에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. Close Comfort EASY FOCUS 4 페이지. Personal
Close Comfort EASY FOCUS에 대해서도 마찬가지입니다: 사용자 설명서 (5 페이지), 사용자 설명서 (5 페이지)

6
WARNING LIGHTS
POWER LIGHT (GREEN)
The power light will come on as soon as the unit is turned on (by opening the rear flap,
or pressing the Power button on the remote).
When the green light is flashing, the compressor is not on however the fan should still
be running. After about 1-2 minutes, the compressor will start cooling and the green
light should be constantly on.
SYMPTOM 1 – GREEN LIGHT IS NOT ON WHEN TRYING TO TURN ON THE UNIT
1) Check to see if the power supply is properly connected and on. The unit will make a
"beep" sound when plugged in to power. If needed, try a different power supply.
2) Check to see if the cable drawer is inserted properly and flush with the body of the
unit. If it is, check if the tip is broken (located at the back of the drawer and protrudes)
– if this is the case, contact us to receive a replacement tank
SYMPTOM 2 – GREEN LIGHT CONTINUOUSLY FLASHING, BUT UNIT IS NOT COOLING
1) If the flashing pattern is continuously on and off and the fan is running, press the
'FUNC' button on the remote and switch to cooling, and change the temperature to
17°C. Wait 1-2 minutes for the green light to display without flashing and start cooling
2) If the green light flashes repeatedly but the fan is not running, this may be due to the
A/C's surge protection mode or an unstable power supply. Turn off the unit using the
remote and close the rear flap. Unplug the unit and wait for 5 minutes. When
reconnecting to the power supply, a "beep" sound will be heard. Repeat this step if its
not heard, and then turn on the unit as per normal.
3) If the problem still continues to persist, this may indicate a fault. Contact us for a
warranty replacement.
WATER DROP (WHITE)
Normally this light should not display. If it does, either;
1) Water tank is full – carefully remove the tank and empty the water
2) Broken float tip – we will send out a replacement tank under warranty
SNOWFLAKE (BLUE)
Normally this light should not display. If it does it can be due to the ambient
temperature being too cool for the unit. Close comfort is designed to be used in a
temperature over 17°C although a certain combination of cold temperature, humidity
and atmospheric pressure can lead to frosting.
SYMPTOM 1 – BLUE LIGHT IS ON, FAN RUNNING
If the temperature is above 17°C, let the unit run cooling as per normal, the fan will help
to defrost the compressor.
SYMPTOM 2 – BLUE LIGHT IS ON, FAN NOT RUNNING
Contact us as the unit may need to be replaced or repaired under warranty.
Another reason the snowflake warning light may display is if there is excessive clogging
in the front filter or if the inlet is blocked by an object, such as the over hanging bed
cover fabric or a cloth.
THERMOMETER (RED)
Normally this light should not display. If it does it can be due to the unit
overheating. Close comfort can be used in an ambient temperature up to 43 degrees.
SYMPTOM 1 – RED LIGHT ON, FAN IS RUNNING
If the temperature is under 43°, let the fan run and it will start cooling automatically
once the compressor is cooled. Make sure to operate in an indoor or shaded outdoor
environment.
SYMPTOM 2 – RED LIGHT ON, FAN NOT RUNNING
Check if the water tank is inserted properly and the tip is not broken
SPECIFICATIONS
SPECIFICATIONS
COOL FOCUS
Electrical supply
2
200 – 240 V 50Hz 1.3 Amp
Minimum operating voltage
185 V
Electrical power while cooling
300 W, DC inverter technology
Compressor type
Reciprocating
Cooling capacity
800 – 1200 W (0.22 – 0.34 tonne)
Cooled air ow
80 – 125 m
3
/hr, variable
Condensed water
Re-evaporated, can be collected
Air temperature reduction
8 – 10 °C at 33 °C, 80% RH
Refrigerant
R134a, 333g
2021 models & later - R290, 80 g
Power cord storage drawer
130 x 150 x 130 mm
Operating environment
20 – 40 °C, 0 – 90% RH
Width
273 mm
Depth
385 mm
Height (covers closed)
550 mm
Weight (unpacked)
17 kg
Noise
46 – 54 dB
Wheels
4 caster wheels
Remote control
Infrared with fan, temperature controls
Piping, plumbing
Not required
Consumables
Not required
Filter cleaning
Check every two weeks
(front, top, rear)
7
EASY FOCUS
200 – 240 V 50Hz 1.4 Amp
185 V
320 W
Reciprocating
800 – 1100 W (0.22 – 0.31 tonne)
115 m
3
/hr
Re-evaporated, can be collected
9 °C at 33 °C, 80% RH
R134a, 333g
1
2021 models & later - R290, 80 g
1
130 x 150 x 130 mm
20 – 40 °C, 0 – 90% RH
273 mm
385 mm
550 mm
17 kg
51 dB
4 caster wheels
No remote, simple on-o control
Not required
Not required
Check every two weeks