9
TROUBLESHOOTING
FAN RUNS BUT THERE IS NO COOLING
SYMPTOM
- Green light is flashing, fan is running but there is no cooling, and
compressor does not start
CURE
- Press FUNC to make the snowflake symbol appear and lower the thermostat
temperature. This is due to the thermostat setting being higher than room
temperature or function is set to "fan" instead of "cooling". We recommend keeping it
set to 17°C and on "cooling" at all times.
FAILS TO START
SYMPTOM
- Air conditioner does not start, green light flashes 6 times, then pauses and
repeats
CURE
- Disconnect the power - either switch off the power point or remove the power
lead for 5 minutes. To avoid the problem, when you have finished using your close
comfort AC, siwtch it off with the remote control before closing the warm air cover
SYMPTOM 2
- Green power warning light flashes, air conditioner does not start
CURE
- Remove the Cable drawer and insert back in correctly or empty water collected.
If water has accumulated, this may indicate a fault as it will gernerally not fill with
water unless in the most humid conditions. Wait 10-15 minutes and restart the air
conditioner.
ROOM SEEMS TO WARM UP
SYMPTOM
- The room gets warmer with Close Comfort running.
CURE
- As you become used to the cool microclimate that Close Comfort provides for
you, the other parts of the room may seem to be warmer. There may be a slight increase
in temperature by a few degrees only in the area behind the warm air cover, but this
wont be significant enough to heat up the room.
Keep a door or window open (this is a healthy option in any case) and position the rear
section of the unit to face the open window or door so warm air can flow out. Unlike
normal room air conditioners, Close Comfort works just as well with open doors/win -
dows and fresh air circulating
GRADUAL LOSS OF COOLING
SYMPTOM
- Air conditioner loses it's cooling effect gradually over time.
CURE
- Clean the top, front and rear filters by removing them and rinsing under running
water. Household dust can accumulate on the filters over time and this can gradually
reduce the air flow, reducing the apparent cooling.
SPECIFICATIONS
SPECIFICATIONS
COOL FOCUS
Electrical supply
200 – 240 V 50Hz 1.3 Amp
Minimum operating voltage
185 V
Electrical power while cooling
300 W, DC inverter technology
Compressor type
Reciprocating
Cooling capacity
800 – 1200 W (0.22 – 0.34 tonne)
Cooled air ow
80 – 125 m
3
/hr, variable
Condensed water
Re-evaporated, can be collected
Air temperature reduction
8 – 10 °C at 33 °C, 80% RH
Refrigerant
R134a, 333g
2021 models & later - R290, 80 g
Power cord storage drawer
130 x 150 x 130 mm
Operating environment
20 – 40 °C, 0 – 90% RH
Width
273 mm
Depth
385 mm
Height (covers closed)
550 mm
Weight (unpacked)
17 kg
Noise
46 – 54 dB
Wheels
4 caster wheels
Remote control
Infrared with fan, temperature controls
Piping, plumbing
Not required
Consumables
Not required
Filter cleaning
Check every two weeks
(front, top, rear)
SUPPORT
General & Troubleshooting FAQ's can be found on our support pages on
our website at www.closecomfort.com, and are updated frequently. For
any general, support, warranty or technical enquiries please contact us at
[email protected] or visit us at www.closecomfort.com to find
your local retailer & service agent information, and your local customer
support phone numbers.
CLOSE COMFORT AUSTRALIA PTY LTD
SUITE 6 /18 STIRLING HIGHWAY
NEDLANDS WA 6009
T: +618 9386 3257
www.closecomfort.com
10
EASY FOCUS
200 – 240 V 50Hz 1.4 Amp
185 V
320 W
Reciprocating
800 – 1100 W (0.22 – 0.31 tonne)
115 m
3
/hr
Re-evaporated, can be collected
9 °C at 33 °C, 80% RH
R134a, 333g
2021 models & later - R290, 80 g
130 x 150 x 130 mm
20 – 40 °C, 0 – 90% RH
273 mm
385 mm
550 mm
17 kg
51 dB
4 caster wheels
No remote, simple on-o control
Not required
Not required
Check every two weeks