ASHAPOWER ROVER-5000LV-48V 사용자 설명서 - 페이지 10

{카테고리_이름} ASHAPOWER ROVER-5000LV-48V에 대한 사용자 설명서을 온라인으로 검색하거나 PDF를 다운로드하세요. ASHAPOWER ROVER-5000LV-48V 14 페이지. Solar mppt pcu

How to enter Quick customer settings menu
Press OFF button on the front panel
Press and hold ENTER button for 3 seconds.Device enters Quick settings mode
displaying UPS mode ON/OFF selection option.Cooling fan starts functioning.
Select the required option by pressing ON/OFF button
Press ENTER button again to go to next menu
To exit Quick settings menu go through all menu or keep the device idle for 8 seconds
What is UPS mode in Quick settings menu.
UPS mode is to shift the connected load on inverter from grid power to battery
power when grid power drops below 190V.
Fluctuations on grid power badly affect digital equipments as computers.
When the device is used for digital equipments as computers select UPS mode
in ON position. In this mode device automatically shifts from grid mode to
inverter mode when AC mains voltage drops below 190V preventing frequent
computer system restarting.
What is INVERTER mode
In this mode device shifts the load to inverter when the mains voltage drops below 100V
Which mode is better for house hold equipments
If UPS mode is activated in low grid power voltage areas (below 190V) load will be working
on battery backup , resulting more grid energy consumption for charging.So it is better
to activate INVERTER mode for normal house hold equipments as fans LED lights,mixer grinder
washing machines etc.
What is CHARGER ON/OFF in quick settings menu
This option helps the customer to control charging of batteries (ON/OFF) from grid power saving
electricity.
When solar power availability is weak grid charging option must be kept in ON
mode to avoid battery deep discharging.
What is SOL-GRD-Kwh in quick settings menu
(The default value 10KWH is an average of 3.5 units from 1KW
solar panels to 12V /200Ah battery)
How to enter main customer settings menu
Before entering settings menu ensure to OFF the device by pressing OFF button
Press OFF button again and press ENTER button also without releasing OFF button
for 3 seconds.With a beep sound device enters main settings mode.Cooling fan starts
functioning
Consecutive pressing of the ENTER button helps to go to next menu.If kept for
5 seconds system saves the changes and exits from settings menu.
Follow the settings table given below.Refer battery user guide lines also
before changing the settings.Remember blind settings will spoil
the device and batteries.
20 MENU CUSTOMER RELATED SETTINGS ARE PROVIDED.
OTHER ADVANCED SYSTEM SETTINGS ARE PASSWORD PROTECTED.
MAIN TECHNICAL SETTINGS GUIDE LINES
10