Dolby Laboratories 493 설치 지침 매뉴얼 - 페이지 5
{카테고리_이름} Dolby Laboratories 493에 대한 설치 지침 매뉴얼을 온라인으로 검색하거나 PDF를 다운로드하세요. Dolby Laboratories 493 6 페이지. Auto digital adapter for da20 / cp200
Signals "CTRL0 through CTRL7" are used to control and read status from the CP200 via the Cat.
No. 493 Auto Digital Adapter board. The DA20 is connected directly to the Cat. No. 493 adapter
board using a 25 pin shielded cable.
1 CTRL0
2 CTRL1
3 CTRL2
4 CTRL3
5 CTRL4
6 CTRL5
7 CTRL6
8 CTRL7
9 N.C.
10 N.C.
11 N.C.
12 GND
13 N.C.
14 SENSE0
15 N.C.
16 N.C.
17 N.C.
18 N.C.
19 N.C.
20 N.C.
21 N.C.
22 N.C.
23 N.C.
24 N.C.
25 C/O STATUS
DA20 to CP200 Sense/Control Wiring Table
DA20 J6
DB25 Male
Pin Number
1 SW Control / B21 of SK13 and M of SK28 (Soldered)
2 Assert GO Button
3 Format A Assert
4 Format B Assert
5 Format C Assert
6 Format D Assert
7 GO Button Monitor
8 Future 11 / A19 of SK27 (Soldered)
9 N.C.
10 N.C.
11 N.C.
12 GND / BS23 Pin 5
13 N.C.
14 Future 8 / Pin 14 of SK15 (Soldered)
15 N.C.
16 N.C.
17 N.C.
18 N.C.
19 N.C.
20 N.C.
21 N.C.
22 N.C.
23 N.C.
24 N.C.
25 Projector 2 / BS23 Pin 6
Cat No. 493
DB25 Female
Pin Number/
CP200 Back Plane