{카테고리_이름} 3M GVP Series에 대한 사용자 지침을 온라인으로 검색하거나 PDF를 다운로드하세요. 3M GVP Series 11 페이지. Belt-mounted powered air purifying respirator assembly

Breathing Tube
GVP-122, GVP-123, H-115, L-122 breathing tubes
Screw the threaded end into the GVP PAPR outlet port (Fig. 2).
Fig. 2
BT-Series breathing tubes
1. Screw the 3M™ Adapter V-199 into the GVP PAPR outlet port.
2. Attach the BT breathing tube to the adapter by inserting the tube end with two prongs into the top of the adapter. Twist the end of the tube
to lock it in place (Fig. 3).
Fig. 3
Belt GVP-117, GVP-127 or TR-326 when used with the GVP-111 or BP-15 battery packs
If using the CB-1000 comfort belt refer to separate User Instructions for information on assembly.
1. Thread the belt through the belt slots on the back of PAPR motor blower.
2. Attach battery pack:
• GVP-111: Thread the belt into the belt slot on the back of the battery pack. (Placing the GVP-111 battery pack onto the belt last will
allow for easier removal for charging.)
• BP-15: Battery pack can slide on and off or be clipped to the belt. Ensure that the bottom edge of the belt is in the bottom of the "J"
potion of the clip.
3. Connect the power cord to the battery pack and the PAPR unit as described earlier.
4. Secure the belt to your waist and adjust for a snug fit. Feed any excess belt length through the belt loop or cut to the desired length.
Belt GVP-117, GVP-127 or TR-326 when used with the TR-630 battery, TR-659 battery
Adapter and holster
1. Thread the belt through the belt slots on the back of PAPR motor blower.
5
Assembly of the TR-630 battery, TR-659 battery adapter and holster
Attaching the TR-630 battery to the TR-659 battery adapter:
2. Insert the TR-630 battery pack into the TR-659 battery adapter by sliding the hinged side of the battery into the corresponding side of the
adapter (side with power button) (Fig. 4).
Fig. 4
3. Push down the TR-630 battery so that it is fully seated in the adapter and the blue release tab on battery clicks into place (Fig. 5).
Fig. 5
Inserting the TR-659 battery adapter with battery into TR-656 heavy duty holster
4. If not already done, unbutton the clip holding the top flap of TR-656 heavy duty holster in place. Fold top flap of the holster back so it is
ready to accept the adapter and battery.
5. The heavy duty holster can be worn on either side of the waist belt. If choosing to wear the battery and holster on right side of waist belt,
slide the TR-659 adapter with battery into the TR-656 heavy duty holster with battery side facing belt loop (back) of the holster (Fig. 6).
Fig. 6
6